Adjustment Of The Motor Encoder And Shaft Encoder - KEB Combivert F5 Instruction Manual

Lift
Hide thumbs Also See for Combivert F5:
Table of Contents

Advertisement

Parameter Description
Inverter status
Error „E.EncC"
Please con-
sider LC.31 and/or
chapter 2.3.
Error „E.Enc1"
Error „E.Hyb"
LC.03
Encoder alarm mode
Input
0
2
8
10
LC.11
Display Interface 1
Shows which encoder interface is installed and thus which encoder may be connected to channel 1 (X3A).
Value
Installed encoder interface
0
none
11
Hiperface
12
Incremental encoder input 24 V HTL
13
Incremental encoder input TTL with error detection
14
SIN/COS
15
Incremental encoder input 24 V HTL with error detection (push-pull)
16
ENDAT
17
Incremental encoder input 24 V HTL with error detection
19
Resolver
Value Description
The correct evaluation of the system position is no longer ensured. The error E.EncC can
only be reset via parameters Ec.00/LC.11.
Exception ! An error, due to wrong encoder increments (value 70), is immediately reset,
once the correct encoder increments are adjusted. Attention, if the control release is still
set, the modulation is enabled !
64
Encoder unknown and not supported.
68
No encoder connected of encoder breakage detection has tripped.
69
System deviation too large. The position, determined from the incremental signals,
and the absolute position (from absolute track, zero signal or serial read) no longer
match or cannot be corrected.
see LC.12/ LC.22!
70
Adjusted increments do not match the encoder increments.
71
Interface type is unknown: Interface was not identified.
75
Encoder temperature is too high (message from encoder)
76
Speed is too high (message from encoder)
77
Encoder signals are outside the specifications (message from encoder)
78
Encoder has an internal defect (message from encocer)
92
Encoder is formatted. When writing on an encoder, whose storage structure does
not correspond to the KEB definition, the storage areas are reorganized, so that
they can be written on. Depending on the storage structure, this process can take
several seconds.
96
New value recognized, because another encoder was plugged in.
98
Interface is busy.
During read out of the encoder the error „E.Enc1" is output.
97
KEB identifier undefined. Storage structure of the encoder does not correspond to
the KEB definition, thus data cannot be read. By writing on it the encoder is defined.
The error can be reset as follows:
• Writing a system position into Ec.2.
• Carry out a system position alignment .
0
No communication between interface and control board
255
Setting
Description
x
off
Channel 1
Channel 2
Channel 1 and 2
continued on next page
GB - 31