Download Print this page

IBM 2030 Manual Of Instruction page 322

Processing unit, field engineering

Advertisement

TEST INDICATOR
The Test Indicator comes on when
either the Rate Switch, the Address
Com.pare Switch, the Check Control
Switch, or the ROS control switch
are not in the Process position.
When on, the Test light indicates
that a test is in progress.
The Test Indicator is located on
logic page PA 061.
LeAD INDICATOR
The Load Indicator comes on when the
Load Rey is pressed and turns off at
the completion of the initial pro-
gram load sequence.
When the Load Indicator turns off,
it means that the input device has
finished reading in the new program
and that the new PSW has been
loaded.
The Load Indicator is located on
logic page PA 061.
DATA AND ADDRESS ENTRY SWITCHES
Allow manual entry of data and
addresses to the CPU.
Each switch provides more than one
function.
Data and addresses are entered with
correct parity.
pescription
Eight rotary switches are provided for
entering manual data or addresses into
the system.
Each of these is a sixteen-
position switch which pro:vides one hexa-
decimal digit, or four bits plus parity.
Th~
first four switches, labeled A, B,
C, and D are used to set up the address
for manual operations of the core stor-
age, or to set up a compare address.
The switches labeled F, G, H, and J are
used to set up an Instruction Address, a
ROS Address, a Load Unit Address, or
manual data.
6-10
The following chart shows the switch-
es used to perform the various
functions.
r------------T--------,
I
I
Switches
I
I
fUnctions
I
Used
I
.-------------------+-----------~
I
Compare ROAR
J
I
,Stop Address
IA,B,C,D
I
r---·
----.-------+--------~
I
Compare ROAR
I
I
,Restart Address
IA,B,C,D
I
r-----~---
-
----+-----------~
,Compare SAR
I
I
IRestart Address
IA,B,C,D
I
.--------------------+-----------~
I Compare SAR
I
I
Istop Address
IA,B,C,D
I
.--------.....,..------+---------~
JHanual Display
I
I
lor Store Address
lA, B, C, D I
.-------------------t-----------~
I
Instruction Address IF,G,H,J
,
-.---------------+----------~
IROS Address
IF,G,H,J
I
.-------------------t-·
----~
ILoad Unit Address
I
I
I
(IPL)
I
G, H,
J
I
.---------------t--------~
,Store Data
IB,J
I
_~
__
~_-------~-~---
__ ------J
DISPLAY STORAGE SELECTION
Two concentric switches at one loca-
tion.
Inner switch has 3 positions; outer
switch has 16 positions.
Define register or storage area to
be addressed on a display Or store
operatioJ'l.
DESCRIPTION
The Display/Storage Selection switch
(switch E) provides a means of selecting
a register or one location of main stor-
age or auxiliary storage, in order to
display or store information.
Selection
is made according to the following
table.