H-Adjusting Thermostat Set Point Differential; I-Changing The Temperature Scale Display Mode - Traulsen G Series Owner's Manual

Reach-in & pass-thru refrigerators, reach-in & pass-thru hot food holding cabinets, reach-in freezers, hinged glass door refrigerators (for equipment produced after 01-2010 only)
Hide thumbs Also See for G Series:
Table of Contents

Advertisement

VII. h – ADJUSTING THE SET POINT DIFFERENTIAL:
This parameter sets the number of degrees the air temp will rise above set point before the refrigeration system will cycle
on. The set point differential is set at 2 for both refrigerator and freezer models which will allow the air temperature to rise 2
degrees above SP (set point) setting before cycling refrigeration on. This parameter is preset at the factory and does not
require adjustment unless the customer chooses to do so.
Follow the instructions to enter the customer access code on page 8. When the control
displays
Thermostat Set Point, press the down arrow key
display reads
Use the arrow keys
When the display shows the temperature you want press the set button
The display will then read
You can use the up or down arrow keys to scroll to the next parameter
or wait 30 seconds for the control to return to normal operation.
VII. i - CHANGING THE TEMPERATURE SCALE DISPLAY MODE:
The temperature scale determines if the temperature displayed will be in degrees
Fahrenheit or degrees Celsius.
Follow the instructions to enter the customer access code on page 8. When the control
displays
Thermostat Set Point, press the down arrow key
display reads
Temperature Scale. Press the set button
The display will start with the current setting either
or
for degrees Celsius. Use the arrow keys
When the display shows the scale you want press the set button
The display will then read
You can use the up or down arrow keys
or wait 30 seconds for the control to return to normal operation.
VII. MICROPROCESSOR CONTROL (cont'd)
Thermostat Set Point Differential. Press the set button
to adjust the temperature to your desired setting.
Thermostat Set Point Differential.
Temperature Scale.
until the control
SET
until the control
SET
.
for degrees Fahrenheit
to toggle between the options.
.
SET
to scroll to the next parameter
-10-