Start-Up
4-26
Instruction
Convert Double
If EN = 1, convert
Word Integer to
the double word
a Real
integer i to a real
number o.
Convert a Real
If EN = 1, convert
to
a
Double
the real number i
Word Integer
to a double word
integer o.
Instruction
Jump to Label
If EN = 1, go to
label n.
Label
Label marker for
the jump.
Conditional
If EN = 1, exit the
Return from
subroutine.
Subroutine
Conditional End
If EN = 1, END
terminates the
main scan.
If EN ↑, go to
Subroutine
subroutine n.
CONVERSION OPERATIONS
Ladder Symbol
DI_REAL
EN
ENO
OUT
IN
TRUNC
ENO
EN
OUT
IN
Ladder Symbol
n
JMP
n
LBL
RET
END
n
SBR
EN
x1
x3
x2
(x... optional parameters)
Valid Operands
Enable:
EN
In:
VD, ID, QD, MD, AC,
Constant, LD
Out: VD, ID, QD, MD, AC,
LD
Enable:
EN
In:
VD, ID, QD, MD, AC,
Constant, LD
Out: VD, ID, QD, MD, AC,
LD
Valid Operands
Enable:
EN Label:
WORD: 0-127
Label:
WORD: 0-127
Enable:
EN
Enable:
EN
Label:
Constant : 0-63