Advertisement

Normal booting (Start-up switch position 0)
Booting with default machine data (Start–up switch position 1)
Booting with saved data (Start–up switch position 3)
Contrast control
SINUMERIK 802S base line
Start-Up
The control system changes to the JOG/Ref.point approach mode and the
yellow LED DIAG flashes (see Fig. 2–6).
This initial state is the precondition for error–free start–up of the control
system.
When the control system is already turned on, start–up is also possible in the
Diagnosis menu (see User Manual).
User data exist, no
boot error
Data in user memory
faulty
The user memory area not loaded with default data is erased,
and the default machine data are loaded from the permanent memory into
the user memory.
The user data backed–up on the permanent memory are loaded into the
user memory.
See User's Guide "Operation and Programming"
Result
Control system changes to
JOG/Ref.point approach mode,
yellow LED DIAG (see Fig. 4–1) flashes.
Backed–up user data are loaded from the permanent
memory into the user memory (as in start–up switch
position 3). If no valid user data are in the permanent
memory, the default data are loaded (as in start–up
switch position 1).
Any deviations from normal booting are displayed on
the screen.
Result
Result
Start-Up
4-7