Definition of MD 14510
MD14510
Machine data
Index
WORD (16 bits Integer)
14510[12]
Definition: Time setpoint for feed/spindle override. Press and hold on feed/spindle decrease
key more than the setpoint , the override shifts to 0% and 50% directly
Unit: 100ms
Range: 5 ~ 30(0.5 ~ 3 seconds), if overrun, the default is 1.5s
14510[13]
Definition: Time setpoint for feed/spindle override. Press and hold on feed/spindle 100% key
more than the setpoint , the override shifts to 100% directly
Unit: 100ms
Range: 5 ~ 30(0.5 ~ 3 seconds), if overrun, the default is 1.5s
Definition: Machine tool type
14510[16]
Unit: -
Range:
Definition: Drive type
14510[17]
Unit: -
Range:
Definition: number of positions on the turret
14510[20]
Unit: -
Range:
Definition: monitor time (turret change abort if destination tool not found within specified time)
14510[21]
Unit: 0.1 second
Range:
Definition: Turret clamping time
14510[22]
Unit: 0.1 second
Range:
Definition: Braking time of external brake mechanism of a contactor controlled spindle
14510[23]
Unit: 0.1 second
Range:
Definition: Interval of track lubrication
14510[24]
Unit: 1
Range:
Definition: Duration of lubrication
14510[25]
Unit: 0.1 second
Range:
Definition: X axis + traverse key position
14510[26]
Unit: -
Range:
Definition: X axis - traverse key position
14510[27]
Unit: -
Range:
Definition: Y axis + traverse key position
14510[28]
Unit: -
Range:
Definition: Y axis – traverse key position
14510[29]
Unit: -
Range:
Definition: Z axis + traverse key position
14510[30]
Unit: -
Range:
Definition: Z axis – traverse key position
14510[31]
Unit: -
Range:
SINUMERIK 802S base line
Start-Up
0 - Turning machine; 1 - Milling machine; >2 not defined
0 – stepper drive; 1 – analog drive (SimoDrive 611); >2- not defined;
4, 6, 8 (note: for SAMPLE only 4 / 6 permitted)
30 ~ 200 (3 ~ 20 second)
5 ~ 30 (0.5 ~ 3 second)
5 ~ 200 (0.5 ~ 20 second)
Minute
5 ~ 300 Minutes
10 ~ 200 (1 ~ 20 second)
between 22 ~ 30, but not 26
between 22 ~ 30, but not 26
between 22 ~ 30, but not 26
between 22 ~ 30, but not 26
between 22 ~ 30, but not 26
between 22 ~ 30, but not 26
USER_DATA_INT
PLC Machine Data – Integer
Technical Appendix