Troubleshooting Base Oven; Owner's Manual 1191904 Rev 2 (5/14 - Southbend S Series Owner's Manual

Restaurant ranges
Hide thumbs Also See for S Series:
Table of Contents

Advertisement

S S
R
ERIES
ESTAURANT
T
ROUBLESHOOTING
that components are in place and functioning as intended.
Probelm
Oven will not come on.
Oven pilot will not stay ignited
Figure 8
Troubleshooting Oven Pilot
Check that the oven pilot adjustment on the gas valve is open.
If the pilot still will not light, do the following: Remove the oven
bottom. Loosen the pilot nut on the burner bracket. Remove the
pilot tube from the safety valve. Remove the pilot orifice from the
pilot or end of the tube and check for debris.
Re-install the pilot orifice and tubing.
If the voltage does not rise above 450 millivolts, then adjust or
clean the pilot assembly to chieve a larger flame. If the voltage
will not adjust properly, then replace the thermopile.
if you continue to have issues after replacing the thermpile, then
contact Southbend Technical Support for assistance at
919-762-7621000 option 2.

OWNER'S MANUAL 1191904 REV 2 (5/14)

R
ANGES
B
O
ASE
VEN
Oven pilot does not work.
Check whether the pilot flame is lit by looking through the hole in
the bottom of the oven. Leave the oven door open for five minutes
to allow gas fumes to clear.
If the pilot is not lit, attempt to light the pilot by raising the kick panel
slightly and rotating its top edge outward. Press and hold the button
on the oven safety valve and put a flame to the pilot.
Does the pilot light?
No
Does the pilot light?
No
CAUTION
Look for -
– Oven pilot is out.
– Pilot gas not adjusted properly.
– Bad thermopile.
– Bad thermopile connections at safety valve.
– Bad safety valve.
– Dirty pilot
– Draft condition.
– Improper ventilation system.
– Air in gas line.
Yes
Continue to hold the button for 30 seconds. The pilot should remain
lit after the button is released. If it does not, wait five minutes and
If the pilot will not remain lit, do the following: Set a multimeter to
the thermopile connections on the safety valve to test the DC
millivolts of the thermopile. While holding the button, light the pilot
and messure the voltage produced by the thermopile. The voltage
should read abobe 450 millivolts.
Yes
If the voltage of the thermopile is oven 450 millivolts, then remove
the thermostat wires and test the pilot again. If the pilot continues
to fail, then replace the safely Value. If you continue to have
issues after replacing the safety valve, then contact Southbend
Technical Support for assistance at 919-762-1000 option 2.
T
ROUBLESHOOTING
try again.
PAGE 25 OF 31

Advertisement

Table of Contents
loading

This manual is also suitable for:

S24 seriesS48 seriesS36 seriesS60 series

Table of Contents