Electrical Component Defects
6.2.3 POWER SUPPLIES
Component
+5v (CN102-4)
+5v (CN102-2, 3)
+12v (CN102-9)
-12v (CN102-8)
+24v (CN111-3, 4, 5, 6)
+24v (CN111-1)
Motor drive board FUSE
FU700(PSU)
FU701 (PSU)
FU702(PSU)
FU703,FU704(PSU)
C279
Condition
No supply
The machine does not turn on.
No supply
The machine does not turn on, but LED103
on the MPU blinks.
No supply
Black stripes in the image.
No supply
The LCD/LEDs on the operation panel do
not indicate.
No supply
E-47 is displayed, and the output mode in
SP mode does not turn anything on except
the main motor.
No supply
E-12 is displayed, and SP5-13, 14, 15
(master eject motor/ pressure plate motor
output mode) do not turn the motor on.
FUSE
The "open cover" indicator is lit.
FUSE
The machine does not turn on.
E-41 is displayed, and the output mode
FUSE
in SP mode does not turn anything on
except the main motor.
E-12 is displayed, and the output mode
FUSE
in SP mode does not turn anything on
except the main motor.
FUSE
E-06 is displayed.
6-18
Symptom
SM