(1) Accessible station when connecting peripheral devices
• When peripheral device is connected to the master station, host station, a local
• When peripheral device is connected to a local station, host station and the
• When peripheral device is connected to a remote I/O station, the master station is
In the system configuration in Fig 5.3, an A6GPP connected to local station No. 1 (L1) can
execute the following operations for the master station.
• Program read/write
• Monitor
• Test
• Remote RUN/STOP/PAUSE
Accessing other station with a peripheral device connected to programmable
controller CPU
When accessing to other station from the peripheral device, the station which can be
accessed depends on types of access source station (master station, local station, or
remote I/O station).
The basic concept is illustrated in Fig 5.3. For details on the executable functions,
refer to the manuals for the peripheral device and module to be used.
station, and a remote I/O station are accessible.
master station are accessible.
only accessible.
Access
source station
M
M
L1
L2
R3
R4
*1: Not accessible when using GX Developer.
Access target station
L1
Fig 5.3 Accessibility between link modules
5 - 16
L2
R3
*1
R4
*1