9.
PROGRAMMING
(2)
[Program example]
For execution only when the write command status is changed from OFF to ON
Executed while the write command is ON
Write program (LWTP instruction)
The following describes the program where the present value of C0 to C9 of the
master station is written to C0 to C9 of the local station No.3.
(For system configuration and link parameter setting, refer to Fig 9.7 and Fig 9.8.)
9 - 39