7.8 Externally turns ON or OFF control output

Turning ON or OFF this input allows remote control
of the control output.
This takes precedence over the output on/off switch
on the panel.
1. Connection
• Use a micro signal switch commensurate with DC8V 4 mA as
the input contacts.
• Connect the "OUT remote" to terminal MC5 or MC6 set as fol-
lows.
2. Setting
• To set the "OUT RMT." ( out remote ), use the "MC5" or "MC6" setting screen within "SWITCH" on the
initial setting screen or the engineer screen.
M
C
5
G A I N 2

7.9 Setting of mechanical loss with two-reel switching

In automatic operation mode, the control output
plus mechanical loss will be generated. In manual
operation mode, the manual control value plus me-
chanical loss will be generated.
In the two-reel winding operation, the system
switches between mechanical loss correction
torque MLA and MLB. If off, the mechanical loss
cancel value for reel A setting is valid. If on, the
mechanical loss cancel value for reel B setting is
valid.
This setting is recommended in the case of the
great mechanical loss in single reel winding.
1. Setting
• To set the mechanical loss, use the "MECH.LOSS" ( mechanical loss ) screen within "REEL" on the
engineer screen.
M
E
C H . L O S S
A - R E E L → # # # %
S E L E C T
M C 5
I N P U T
:
I N C H N G
:
O U T
M E N U #
M C H . L O S S
B - R E E L → # # # %
:
35
MC5
MC6
OUTPUT
ON/OFF Switch
Control output
Out remote
R M T . :
C U T
T R Q .
Select "OUT RMT"
OFF
MC2 input
(rell A)
Mechanical loss
MLA
correction
C O M P E N S A T I O N
Photo coupler
MC5
MC6
1.6kΩ
MCC
8V
OFF
ON (rell B)
(rell A)
MLA
MLB