9.8 Execution of CC-Link

1. Outline
• When the tension controller LE-40MTB-E is linked to the CC-Link network, the data for the tension con-
troller can be set on the master programmable controller and the control status of the tension controller
can be monitored on the master programmable controller. The contact signal information and the data
can be linked each other by simply connecting the FX2N-32CCL type CC-Link interface block for the
FX2N series programmable controller to the extension connector of the LE-40MTB-E.
2. Transmission signal configuration
• By connecting the LE-40MTB-E tension controller to the FX2N-32CCL type interface block, the LE-
40MTB-E works in the same way as the remote device station on the CC-Link network. The system
programm of the LE-40MTB-E is programmed to gain access automatically by executing FROM/TO
commands against the buffer memory of the FX2N-32CCL. Therefore, the data can be sent and re-
ceived by accessing this remote device station (FX2N-32CCL for LE-40MTB-E) through the program
of the master programmable controller.
• The number of available stations for the FX2N-32CCL are four. The LE-40MTB-E occupies three sta-
tions of them, so duplication of the station numbers must be avoided for other remote device stations,
remote I/O stations and remote stations.
The number of connected devices, the transmission speed, and the transmission distance are based
on the common specifications of the CC-Link system. Refer to User's manuals of FX2N-32CCL and
CC-Link master unit for the details.
MC1~MC6
LE-40MTB-E
ZT
Terminal resistor
( indispensable )
Terminal resistor
( indispensable )
FX2N-32CCL
FX2N Series
BFM#0~31
FX
-32CCL
2N
BFM#0~31
three stations
Contact input : 80 + 16
( RX00 ~ 4F + RX50 ~ 5F)
Input data : 12
( Rwr0 ~ B)
54
Master unit
A1SJ61BT11 or
P W
CPU
AJ61BT11
CC-Link
Interface
block
Remote I/O
LE-40MTB -E
Power
Master
supply
CPU
CC-Link
Contact output : 80 + 16
( RY00 ~ 4F + RY50 ~ 5F)
output data : 12
( Rwm0 ~ B)
A/D converting
unit
unit
Master
AX
AY
station
X/Y
00~1F
(16)
(16)
(32)