Blower Resistor - Toyota Tundra 2005 Service - Repair - Maintenance

Hide thumbs Also See for Tundra 2005:
Table of Contents

Advertisement

AC-78
2
4
AIR CONDITIONING

BLOWER RESISTOR

INSPECTION
1.
2.
3.
4.
5.
6.
7.
(a)
(b)
I11127
8.
1
3
If resistance is not as specified, replace the blower resistor.
N09039
9.
(a)
(b)
I11127
10.
11.
12.
13.
14.
15.
-
BLOWER RESISTOR
REMOVE GLOVE COMPARTMENT PARTS
REMOVE LOWER NO. 2 FINISH PANEL
REMOVE LOWER CENTER COVER
REMOVE LOWER LH FINISH PANEL
REMOVE LOWER COVER (See page
REMOVE NO. 4 HEATER TO REGISTER DUCT
REMOVE BLOWER RESISTOR
Disconnect the connector.
Remove the 2 screws and blower resistor.
INSPECT BLOWER RESISTOR RESISTANCE
Tester connection
1-4
1-3
1-2
INSTALL BLOWER RESISTOR
Install the blower resistor with the 2 screws.
Connect the connector.
INSTALL NO. 4 HEATER TO REGISTER DUCT
INSTALL LOWER COVER
INSTALL LOWER LH FINISH PANEL
INSTALL LOWER CENTER COVER
INSTALL LOWER NO. 2 FINISH PANEL
INSTALL GLOVE COMPARTMENT PARTS
(See page
BO-120
Author :
BO-1
Condition
Specified condition
Constant
Constant
Constant
)
Date :
AC23E-05
11)
3.3 ± 0.2 Ω
1.9 ± 0.1 Ω
2.9 ± 0.2 Ω
5105