Connect Power to the Device

CAUTION:
Wrap and fasten one end of the ESD grounding strap around your wrist and connect the other end to a
site ESD point.
NOTE:
Ensure that you ground AC-powered systems by attaching one end of the grounding cable to earth ground
and the other end to the chassis grounding points.
To connect the device to the power supply:
Set the power switch on the device to the off (
1.
Insert the power cord plug into the power source outlet and power cord coupler into the chassis power inlet.
2.
Set the power switch to the on (
3.
Verify that the power LED is lit green and on steadily.
4.
Power Cable Warning (Japanese)
WARNING:
The attached power cable is only for this product. Do not use this cable for another product.
Factory-Default Settings
The NFX150 device is shipped with the following factory-default settings:
Table 1: Security Policies
Source Zone
trust
trust
Table 2: Interface Mapping
Port Label
Interface
0/0 to 0/3
heth-0-0 to heth-0-3
0/4
heth-0-4
0/5
heth-0-5
4
O
) position.
) position.
|
Destination Zone
trust
untrust
Virtual Interface
ge-0/0/0 to ge-0/0/3
ge-1/0/1
ge-1/0/2
Policy Action
permit
permit
Security Zone
DHCP State
trust
Server
untrust
Client
untrust
Client
IP Address
192.168.2.1/24
ISP assigned
ISP assigned