Setting The Parameters With The Display Menu - Lochinvar EcoForce EF80 Installation, Commissioning, User And Maintenance Instructions

Wall mounted gas fired condensing water heater
Table of Contents

Advertisement

S
T
P
ETTING
HE
ARAMETERS
The following table gives a list of parameters that can be programmed by the display. All parameters that are shown in the display can be
changed. NOTICE: Only the password for level 1 is issued in this manual. When other "more advanced" parameters need to be programmed,
it can only be done by a skilled and trained service engineer, who has access to level 2.
In the parameter table shown below are all the parameters that can be set on the unit without the use of a laptop/computer.
In the following chapter "Controlling options and settings" the controlling options for hot water and cascading are explained. In the explanation
of these options there is reference to all relevant parameters which are shown in the table below and can be set on the unit.
PARA-
MENU
METER
1
P5BE
2
P5AO
3
P5AP
4
P5AL
A
5
P2IC
6
P2MI
7
P2MJ
Proportional range System CH temperature control
8
P2MK
9
P5AB
1
P4AB
2
P5CB
3
P5CK
4
P5CL
5
P5CD
6
P5CI
7
P5CJ
8
P2KI
B
9
P2LC
A P2MN
B
P2LD
C P2MO
D
P2ML
E P2MM
F
P5CA
G
P2KH
Gradient heat demand detect DHW tank temperature
1
P2MA
2
P5DA
3
P5DC
C
4
P5DE
5
P5DF
6
P5BL
7
P5DB
Number of water heaters with common flue 0=None
1
P5BB
2
P5AI
3
P5BI
4
P2LK
5
P5BJ
D
6
P4AA
7
P4AD
8
P4BD
9
P4BE
A
P5BN
IMPORTANT:
Do not change the parameters P2LC, P2LD, P2ML, P2MM and P5BI; they are used within the controller for
purposes other than DHW control. Changing these parameters may affect water heater operation negatively!
W
T
D
M
ITH
HE
ISPLAY
When 'Modify = no', the parameter can only be programmed at level 2
DESCRIPTION
Step modulation (1=on 0=off)
Blocking offset flow temperature control
Proportional range temperature control
Hysteresis CH Flow temperature control
Integration time temperature control
Blocking offset System CH temperature control
Integration time CH temperature control
Timer Contact (1=on)
DHW Pump Config 0=Pump 1=TWV
Flow temperature DHW tank low
Flow temperature DHW tank hi
Low Flow temperature time DHW
Legionella temperature
Legionella hyst DHW tank temperature
Legionella hold time (0=off)
CH interrupt by Legionella (0=yes)(1=no)
Regulation temperature offset DHWd
Proportional range DHWd modulation
Regulation temperature hysteresis DHWd
integration time DHWd modulation
Sys temp blocking offset DHW tank
Sys temp blocking hysteresis DHW tank
Hysteresis DHW tank temperature
Max number extra water heaters
Bus address Water heater
Dhw on entire cascade(0) only master(1)
Extra Water heater output enable(1)
Cascade detection (0=standalone 1=Leader)
Power off total cascade (1)
Analogue input Config (0=off 1=temp)
Minimum Temperature 0-10V input
Altitude (in amounts of 100 ft.)
Max cooling time
Temperature display 1=on
DHW 0=off 1=Indirect 2=Direct
pressure 0=off 1=sensor and 2=switch
Gas type values 0-2
Soft start type values 0-2
Pump modes 0-3
ENU
UNITS
-
°C
°C
°C
s
°C
°C
s
-
-
°C
°C
min
°C
°C
min
-
°C
°C
°C
s
°C
°C
°C
°C
-
-
-
-
-
-
-
-
°C
ft*100
min
-
-
-
-
-
-
TEXT DISPLAY
S
t
e
p
m o
H E
s
O
f
H E
s
P
r
H E
s
c
D
i
H E
s
I
n
H E
c
O
f
H E
c
P
r
H E
c
I
n
T
i
m e
r
C o
D H
i
p m p
/
D H
i
f
l
o w
D H
i
f
l
o w
D H
i
L
O
t
L
e
g
i
o
t
L
e
g
i
o
h
L
e
g
i
o
h
L
e
g
i
o
i
D H d
s
c
O
f
D H d
s
c
P
r
D H d
s
c
D
i
D H d
s
c
I
n
D H d
s
c
O
f
D H d
s
c
D
i
D H
i
s
c
D
i
D H
i
d
e
t
g
M a
x
C
a
s
c
B u
s
a
d
r
D H
i
c
a
s
/
E x
t
r
a
u
C a
s
S
i
/
P w
r
O
f
f
T
C o m F
l
u N u m
A n
I
n
p
0
-
1
0 M
i
n
A
l
t
*
1
0
M a
x
C o
o
l
T
e m p O
n D
D H W
1
=
i
c
o
n
f
i
g
g
a
s
t
y
p
e
c
o
n
f
i
g
c
o
n
f
i
g
PASSWORD:
1342
LEVEL 1
Modify
d
u
l
no
f
1
3
yes
b
1
3
no
f
1
3
yes
t
1
3
no
f
3
yes
b
3
no
t
3
no
n
t
yes
t
w
v
yes
L
O
yes
H
I
yes
i
m e
yes
e m p
no
y
s
t
no
o
l
d
no
n
t
r
no
f
2
yes
b
2
3
no
f
2
yes
t
2
3
no
f
3
yes
f
3
yes
f
4
yes
r
a
d
yes
U
n
t
no
e
s
s
no
m a
s
no
n
i
t
yes
M
a
no
o
C
a
no
no
C
o
n
yes
T m p
yes
0
f
t
yes
T
i
m
yes
i
s
p
yes
2
=
d
no
no
no
no
no
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents