Controlling the Monitor with a computer (RS-232C)
Initialization/Functional Restriction Setting (FUNCTION) menu
Function
ALL RESET
ADJUSTMENT LOCK
ADJUSTMENT LOCK TARGET
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
POWER BUTTON
EXTERNAL CONTROLLER INPUT
SIGNAL RESPONSE LEVEL
APPLICATION
APPLICATION RECOVERY MODE
Others
Function
SIZE (Screen size selection)
INFORMATION
Model
Serial no.
Temperature sensor
Temperature acquisition
Cause of last standby mode
FREEZE
LAN setup
FTP ON/OFF select
FTP Username
FTP Password
48
E
Command Direction
Parameter
RSET
W
0-1
ALCK
WR
0
W
1-2
R
ALTG
WR
0-2
LOSD
WR
0-2
OFLD
WR
0-1
TALT
WR
0-2
SALT
WR
0-2
PBTN
WR
0-1
PCIP
WR
0-3
HDUC
WR
1-200
APST
WR
0-1
APRV
W
0
Command Direction
Parameter
WIDE
WR
1-4
INF1
R
SRNO
R
DSTA
R
ERRT
R
STCA
W
0
R
FRMD
WR
0-1
FCHE
WR
0-1
FUSR
WR
XXXXXXXX
XXXXXXXX 8 characters or less; half-width alphanumeric characters, "-", and "_".
FPAS
WR
XXXXXXXX
XXXXXXXX 8 characters or less; half-width alphanumeric characters, "-", and "_".
Reply
Control/Response contents
0: ALL RESET 1, 1: ALL RESET 2
0 OFF
1: ON 1, 2: ON 2
1-2 1: ON 1, 2: ON 2
0-2 0: REMOTE CONTROL, 1: MONITOR BUTTONS, 2: BOTH
0-2 0: ON 1, 1: OFF, 2: ON 2
0-1 0: ON, 1: OFF
0-2 0: OFF, 1: OSD & LED, 2: LED
0-2 0: OFF, 1: OSD & LED, 2: LED
0-1 0: MONITOR, 1: EXT. CONTROLLER
0-3 0: D-SUB, 1: DisplayPort, 2: HDMI1, 3: HDMI2
"ERR" when MONITOR is selected for POWER BUTTON.
1-200
0-1 0: DISABLE, 1: ENABLE
Display the menu for APPLICATION mode recovery
Reply
Control/Response contents
1-4 1: WIDE, 2: NORMAL, 3: Dot by Dot, 4: ZOOM
Value
Value
0 Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby
mode
2 Internal temperature abnormal occurred (To delete the information of
temperature abnormal, turn off the main power.)
3 Internal temperature abnormal has occurred and backlight brightness is
dimmed
4 Temperature sensor abnormal
Value Returns the temperature at the temperature sensors.
Indicates a temperature sensor abnormality when "126" is returned.
Initialization
0 No detectable error has occurred
1 Standby mode by POWER button or MONITOR OFF button
2 Main power off by the main power switch
3 Standby mode by control via RS-232C, LAN, or application
4 Input signal waiting mode by No Signal
6 Standby mode by abnormal temperature
8 Standby mode by SCHEDULE setting
10 Standby mode by HDMI CEC
20 Standby mode by OFF IF NO OPERATION setting
0-1 0: FREEZE release, 1: FREEZE execute
0-1 0: FTP connection OFF, 1: FTP connection ON
"ERR" when DISABLE is selected for APPLICATION.
(The field cannot be left blank, and spaces cannot be entered.)
"ERR" when DISABLE is selected for APPLICATION.
(The field cannot be left blank, and spaces cannot be entered.)
"ERR" when DISABLE is selected for APPLICATION.
*
-
-
*
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pn-hm651Pn-hm751Pn-hb851Pn-hb651Pn-hb751

Table of Contents