Controlling The Monitor With A Computer (Rs-232C); Computer Connection; Communication Conditions; Communication Procedure - Sharp PN-HM851 Operation Manual

Hide thumbs Also See for PN-HM851:
Table of Contents

Advertisement

Controlling the Monitor with a computer (RS-232C)

You can control this monitor from a computer via RS-232C
(COM port) on the computer.
You can also connect multiple monitors via a daisy chain by
using a computer. By assigning ID numbers to each monitor
(see page 39), you can make input mode selection/adjustment
or can check the status of a specific monitor.
TIPS
• To control the monitor via RS-232C, set MONITOR
CONTROL SELECT to RS-232C.
(When this is done, control via LAN or application is not
possible.)

Computer connection

nOne-to-one connection with a computer
Connect with RS-232 straight cable between the computer's
COM port (RS-232C connector) and the RS-232C input
terminal on the monitor.
RS-232C
input terminal
nDaisy chain connection...
Connect with RS-232 straight cable between the computer's
COM port (RS-232C connector) and the RS-232C input
terminal on the first monitor. Next, connect RS-232C conversion
cable (supplied) and RS-232 straight cable to the first monitor's
RS-232C output terminal and to the second monitor's RS-232C
input terminal. Connect RS-232 straight cable and RS-232C
conversion cable (supplied) in the same way to the third and
subsequent monitors.
Up to 4 monitors can be connected. (Depending on the length
of the cable used and the surrounding environment.)
Second monitor
First
monitor
RS-232C
output terminal
RS-232C conversion
cable (supplied)
38
E
To COM port
RS-232 straight cable
(commercially available)
Advanced operation
RS-232 straight cable
(commercially available)
To COM port
RS-232C
input terminal
RS-232 straight cable
(commercially available)

Communication conditions

Set the RS-232C communication settings on the computer to
match the monitor's communication settings as follows:
Baud rate
Data length
Parity bit
* Set to the same baud rate as the BAUD RATE setting of
SETUP menu. (Initial setting: 38400 bps)
* When connecting multiple monitors in a daisy chain, set all
monitors to the same BAUD RATE.

Communication procedure

nCommand format
When a command is sent from the computer to the monitor,
the monitor operates according to the received command and
sends a response message to the computer.
Computer
C1
C2
Command field
(4 prescribed
alphanumerical characters)
Example: VOLM0030
* Be sure to input 4 characters for the parameter. Pad with
spaces (" ") if necessary.
("
" is a return code (0D
Wrong : VOLM30
Right
: VOLM
When inputting a negative value, specify a numerical value in
three digits.
Example: OFSR-127
When the parameter part is 5 or more characters, specify
parameters using a specified number of characters without
using spaces.
Example: MPOS010097
If a command has "R" listed for "Direction" in the
"RS-232C command table" on page 42, the current value can
be returned by using "?" as the parameter.
Computer
Example:
VOLM ? ? ? ?
30
* If an ID number (see page 39) has been assigned
(For example, ID number = 1).
VOLM
30
001
*
Stop bit
8 bits
Flow control
None
C3
C4
P1
P2
Parameter field
(4 character string comprised of:
0-9, +, -, space, ?)
VOLM
30
, 0A
or 0D
H
H
30
From computer to monitor (How
much is current volume setting?).
From monitor to computer
(Current volume setting: 30).
?
From computer to monitor.
From monitor to computer.
1 bit
None
Return code
P3
P4
))
H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pn-hm651Pn-hm751Pn-hb851Pn-hb651Pn-hb751

Table of Contents