Mira Vision Installation Manual page 28

Hide thumbs Also See for Vision:
Table of Contents

Advertisement

Place the backplate over the
outlet pipe with the arrow pointing
vertically up and tighten the two
backplate screws. Make sure that
the foam seal abuts the finished wall
surface.
Check that the blue 'O' seal is fitted
inside the backplate nut. Fit the
olive and the backplate nut over the
outlet pipe, do not tighten the nut
fully at this point.
Check that the second 'O' seal
(black) is fitted to the outside of the
backplate nut. Press the elbow onto
the backplate, make sure that the
clips on the elbow engage with the
backplate.
To prevent the backplate from
turning while tightening the nut, fit
the retaining ring over the backplate
nut making sure the slots engage
with the screws on the backplate,
hold the retaining ring with a wrench
while tightening the backplate nut.
Remove the retaining ring after use.
Slide the retaining ring over the
elbow and engage with the elbow
clips. Note! The retaining ring
must be engaged correctly to lock
the elbow to the backplate, rotate
the retaining ring to the postition
illustrated.
Press the shroud over the elbow,
make sure that it engages with the
lugs on the backplate.
Place first washer in end of hose,
then attach to elbow. Do not fit
showerhead until after pipework
has been fully flushed through. See
section "Commissioning".
Copper
Pipe
28
Backplate
2 x Screws
Copper
Backplate
Pipe
Nut
Olive
Retaining
Ring
Backplate
Foam Seal
Elbow
Retaining Ring shown
correctly engaged with
Elbow
1
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents