Step
Insert the new batteries using correct polarity shown on the battery holder.
6
Insert the battery holder into the transmitter. Reattach the screws and tighten to 0,4 – 0,6 N-M
7
(3.5 – 5.3 Lb-in).
Re-connect battery connector.
Honeywell recommends lubricating the end cap O-ring with a Silicone Grease such as Dow
Corning #55 or equivalent before replacing the end cap.
Screw the end cap back on and tighten the M3 locking screw.
8
Dispose of used battery promptly per local regulations or the battery manufacturer's
9
recommendations. Keep away from children. Do not disassemble and do not dispose of in fire.
6.3

Replacing sensor module

When to replace

Various error messages can help you diagnose a faulty module. These are described elsewhere in this
manual.

Tools required

#1 Phillips Screwdriver or 1/8" Slotted Screwdriver
Torque Screwdriver
1.5 mm hex key

Procedure

WARNING
Risk of death or serious injury by explosion. Do not open transmitter
enclosure when an explosive gas atmosphere is present.
CAUTION
Take precautions against electrostatic discharge to prevent damaging the
sensor module.
Rev. 3
OneWireless XYR 6000 Temperature and Temperature/Discrete Input Transmitter User's Manual
6/24/08