Vermont Castings Radiance RADVT Series Installation & Operating Manual page 33

Direct vent gas heater
Table of Contents

Advertisement

4. An IFT-ECM reset is required if the module is in a lock-out
condition. When this occurs, the appliance is shut down
and the IFT-ECM status indicator LED will be blinking a
RED/GREEN error code along with a one-time audible
double- beep. If the IFT-ECM is in a lock-out condition,
refer to the troubleshooting chart to interpret the error
code and take corrective action as required. To reset the
IFT-ECM after a lock-out error:
CAUTION! Risk of burns! Appliance surfaces are hot
when operating and during cool down. Use care and wear
gloves when opening the front and accessing components
inside the appliance.
- Be aware the appliance may be HOT, use care in
accessing the IFT-ECM.
- Set the IFT-ECM 3-position selector switch to OFF
position.
- Wait five (5) minutes to allow possible accumulated
gas to clear.
- Set the IFT-ECM 3-position selector switch to ON or
REMOTE position. Module will beep once and flash a
three GREEN LED code on successful startup.
- If placed in ON position, the appliance will ignite
normally if the error condition was corrected.
- If placed in REMOTE position, use the paired IFT-
RC400 or wired wall switch to start the appliance;
appliance will ignite normally if the error condition
was corrected.
- If the IFT-ECM re-enters the lock-out condition after
these steps, call your dealer for service.
IntelliFireTM Touch Ignition System
NOTICE: Batteries should not be placed in the battery
pack while using the transformer. Remove batteries before
using the transformer, and unplug the transformer before
installing the batteries. Battery polarity must be correct or
module damage will occur.
Appliance ON/OFF:
This model is supplied with a fully functional remote control.
This remote controls:
• ON/OFF Functions
• Flame height adjustments
• Thermostat
• Cold Climate Feature
• Fan Speed
Please refer to the instructions included with the remote
control for more detailed operating instructions.
3333
Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19
3-90-30007498

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents