Table 8: The Cable > Status Screen - Hitron CVE-30360 User Manual

Up to 400mbps
Hide thumbs Also See for CVE-30360:
Table of Contents

Advertisement

HITRON CVE-30360 USER'S GUIDE
TABLE 8:
The Cable > Status Screen (continued)
Frequency to Tune to This displays the current center frequency in Hertz (Hz)
Scanning Start
Frequency
Channel Frequency
Modulation
Signal Strength
Signal Noise Ratio
Upstream
NOTE:
The upstream signal is the signal transmitted from the CVE-30360.
Channel ID
Upstream Frequency
Upstream Bandwidth
SCDMA Mode
Transmission Signal
Strength
Cable Modem IP Information
IP Address
Subnet Mask
over which data is transmitted to the CVE-30360 over
the CATV interface. This is the frequency to which the
CVE-30360 is locked in; it will only scan for another
frequency if this frequency becomes unavailable.
If you want the CVE-30360 to attempt to connect at a
different frequency, enter it in the field and click Apply.
NOTE:
Do not change the frequency unless you have a
good reason to do so.
This displays the frequency in Hertz (Hz) at which the
CVE-30360 begins scanning for a connection over the
CATV interface (if a frequency is not already locked in).
This displays the actual frequency of each downstream
data channel to which the CVE-30360 is connected.
This displays the type of modulation that each
downstream channel uses. Possible modulation types
This displays the power of the signal of each
downstream data channel to which the CVE-30360 is
connected, in dBmV (decibels above/below 1 millivolt).
This displays the Signal to Noise Ratio (SNR) of each
downstream data channel to which the CVE-30360 is
connected, in dB (decibels).
This displays the ID number of each channel on which
the upstream signal is transmitted.
This displays the frequency in Herz (Hz) of each
upstream data channel to which the CVE-30360 is
connected.
This displays the bandwidth of each upstream data
channel to which the CVE-30360 is connected (in Hertz).
This displays the Synchronous Code Division Multiple
Access (SCDMA) mode of each channel on which the
upstream signal is transmitted.
This displays the transmitted power of the signal of each
upstream data channel to which the CVE-30360 is
connected, in dBmV (decibels above/below 1 millivolt).
This displays the CVE-30360's WAN IP address. This IP
address is automatically assigned to the CVE-30360
This displays the CVE-30360's WAN subnet mask.