The Machine Doesn't Run
Is the Link LED lighted?
Are the network settings correct?
If output is impossible even though the link LED is on, make sure the IP address and other settings are cor-
rect. The settings on both the machine and the computer must be appropriate. Redo the settings, checking
to ensure that the IP address doesn't con ict with the IP address for another device on the network, that the
port setting for the software RIP speci es the IP address set on the machine, that the settings have no typing
errors, and for other such problems.
"Setup Guide," p. 94, "Viewing Information about the System of This Machine"
Did the software RIP end abnormally?
Make sure the software RIP is running correctly, then switch the sub power switch o and back on.
"Roland VersaWorks Quick Start Guide"
Is the temperature of the room too low?
Use the machine in an environment where the temperature is 20 to 32°C (68 to 90°F).
6
98
If the Link LED for the Ethernet connector is not lighted, it
means that a correct connection to the network has not
been made. Make sure the network routing is suitable. Try
connecting the computer and the machine to the same hub,
Link LED
or connecting them directly using a crossover cable. If this
makes it possible to perform output, it means the problem
is in the network itself.