Optional Mid-Stop Limit Setting

The operator includes a programmable Mid-Stop. This feature allows
the operator to stop at a user selectable point when opening. It is used
when operating very tall doors that only open to their full height
occasionally. The Mid-Stop does not effect the operator when closing. To
operate door to full open position from mid-stop, press open button again.
NOTE: Setting of the MID-STOP should only be performed AFTER Travel
Limits have been set and door has been cycled fully open and then
fully closed.
1) Press CAL/RUN
to enter calibration mode.
CAL
RUN
2) Press the CLOSE
to close the door to the down limit.
CLOSE
until display reads "MID-STOP > CLR" Figure 14.
3) Press SCROLL
SCROLL
NOTE: If the display reads MID-STOP > SET at this point, first clear the
MID-STOP as described below then repeat steps 1-3 and continue.
4) Press the OPEN
to open the door to desired mid-stop height.
OPEN
until the display reads "MID-STOP > SET"
5) Press SET/CLEAR
SET
CLEAR
CAL
6) Press CAL/RUN
to return to run mode.
CAL
N
RUN
To CLEAR the Limit
L
1) Press CAL/RUN
CAL
to enter calibration mode.
RUN
until display reads "MID-STOP > SET"
3) Press SCROLL
CROLL
until the display reads " MID-STOP > CLR"
5) Press SET/CLEAR
SET
CLEAR
8) Press CAL/RUN
to return to run mode.