SIS Configuration
and Control
The IN1804 series scalers can be configured and controlled via Extron Simple Instruction
Set (SIS) commands when connected to a host computer or other device (such as a control
system). Attach the host device to the rear panel RS-232 connector or LAN connector, or
to the front panel USB port. Commands can be entered using a Telnet application such as
the Extron DataViewer, available at
details). The default protocol for the RS-232 connection is 9600 baud, 8 data bits, 1 stop
bit, no parity, and no flow control. This section describes SIS communication and control.
Topics in this section include:

Host and Scaler Communication

SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the scaler determines that a
command is valid, it executes the command and sends a response to the host device. All
responses from the scaler to the host end with a carriage return and a line feed
(CR/LF = ] ), indicating the end of the response character string (one or more characters).

Copyright Information

The copyright message is displayed upon connecting to a scaler via TCP/IP or Telnet or
after a power cycle via RS-232, and depends on the scaler model.
]
Ddd, DD MMM YYYY HH:MM:SS
Host and Scaler Communication
SIS Overview
Command and Response Tables for IN1804 SIS Commands
(c) Copyright YYYY, Extron Electronics, IN1804 <model>, Vn.n, 60-1699-0n
] (day, date, and time as in
is the firmware version number.
Vn.nn
is the model part number.
60-1699-0n
is the year.
YYYY
IN1804 Scaling Presentation Switcher • SIS Configuration and Control
www.extron.com
(see the DataViewer Help file for more
Mon, 18 Oct 2018 11:27:33
]
)