Furniture Mounting - Extron electronics IN1804 Series User Manual

Scaling presentation switchers scalers
Hide thumbs Also See for IN1804 Series:
Table of Contents

Advertisement

UL guidelines for rack mounted devices
The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the
scaler in a rack.
1.
Elevated operating ambient temperature — If the equipment is installed in a closed
or multi-unit rack assembly, the operating ambient temperature of the rack environment
may be greater than room ambient temperature. Therefore, install the scaler in an
environment compatible with the maximum ambient temperature (Tma = +122 ˚F,
+50 ˚C) specified by Extron.
2.
Reduced air flow — Install the equipment in a rack so that the amount of air flow
required for safe operation of the equipment is no compromised.
3.
Mechanical loading — Mount the equipment in the rack so that a hazardous
condition is not achieved due to uneven mechanical loading.
4.
Circuit overloading — Connect the equipment to the supply circuit and consider the
effect that circuit overloading might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when
addressing this concern.
5.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct connections
to the branch circuit (for example, use of power strips).

Furniture Mounting

Go to www.extron.com, for a list of available furniture mounting kits. To install the scaler to
furniture, follow the mounting kit instructions.
Figure 56.
Under-Desk Mounting
IN1804 Scaling Presentation Switcher • Reference Information
99

Advertisement

Table of Contents
loading

Table of Contents