Reset Modes

The IN1804 series scalers have three reset modes (numbered 1, 4, and
5). Use a small screwdriver or stylus to press and hold the recessed
Reset
through the modes. The Reset LED (
that is enabled (see the Reset Mode Summary table for a description of
the reset modes and how to select them).
You can also perform resets using the OSD (see
the
page 74), and PCS (see the IN1804 Series PCS Help file).
ATTENTION:
NOTE: The reset modes listed close all open IP and Telnet connections and all sockets.
Mode
Activation
1
Using an Extron Tweeker or other small
screwdriver, press and hold in the
recessed Reset button for 30 seconds
while applying power to the scaler.
NOTE:
After a mode 1 reset,
update the device with the latest
firmware version. DO NOT
operate with the firmware version
that results from this mode reset.
This temporarily resets the device
to factory default until power is
recycled. To use factory default
firmware, upload that version
again.
4
Hold down the Reset button until the
Reset LED blinks twice (approximately
6 seconds). Then, press Reset
momentarily (less than 1 second).
5
Hold down the Reset button until
the Power LED blinks three times
(approximately 9 seconds). Then,
press Reset momentarily (less than
1 second).
button on the rear panel (see
submenu on page 41), SIS commands (see the
Advanced
Review the reset modes carefully. Using the wrong reset mode may result in
unintended loss of flash memory programming, port reassignment, or processor
reboot.
Étudier de près les différents modes de réinitialisation. Appliquer le mauvais mode
de réinitialisation peut causer une perte inattendue de la programmation de la
mémoire flash, une reconfiguration des ports ou une réinitialisation du processeur.
Each mode is a separate function, not a continuation from mode 1 to mode 5.
Reset Mode Summary
The device reverts to the factory default
firmware.
Firmware reverts to the factory default for a
single power cycle.
All user files and settings (drivers, audio
and video adjustments, IP settings, and so
on) are maintained.
NOTE:
firmware or perform a mode 1 reset by
mistake, cycle power to the device to
return to the firmware version running
prior to the reset.
IP settings revert to factory defaults.
Port mapping reverts to factory default.
DHCP turns off.
IP address is set to 192.168.254.254.
Reset LED blinks four times in quick
succession during reset.
The device reverts to the factory defaults
except for firmware.
Mode 4 results are performed.
All user modifiable configurations reset to
default values including IP settings and
real-time adjustments.
All user loaded files are deleted.
The Reset LED blinks 4 times in quick
succession during the reset.
in the image at right) to advance
2
) blinks to indicate each mode
1
Factory Reset
Result
If you do not want to update the
IN1804 Scaling Presentation Switcher • Operation
1 2
RESET
1A
1B
HDMI/CEC
HDMI/CEC
on
Resets commands
on
Purpose/Notes
Use mode 1 to revert
to the factory default
version if incompatibility
issues arise with
user-loaded firmware.
Use mode 4 to reset
all IP settings back to
factory defaults.
Use mode 5 to
restart with default
configuration. This
is equivalent to SIS
command ZQQQ.
44