This FRU contains a horizontal top contact cable connector. Read the instructions before proceeding.
The horizontal top contact connector uses a back flip locking actuator to lock the ribbon cable into the Zero
Insertion Force (ZIF) connector. The cable is inserted horizontally into the connector.
Warning—Potential Damage: When opening or closing this type of actuator, gently lift or close the two tabs
located on each end of the actuator. The two tabs should be moved simultaneously. Do not close the
actuator from the center of the actuator.
Removing a cable from the horizontal top contact connector
1
Place a finger at each end of the locking actuator, and then gently lift the actuator to the unlocked position.
2
Slide the cable out of the connector.