Remove The Blade; Test Run - Grizzly G0524 Owner's Manual

Rip saw
Hide thumbs Also See for G0524:
Table of Contents

Advertisement

Remove the Blade

For safety reasons, the saw blade must be
removed before the saw is test run to ensure the
wiring is not reversed at the main terminal (Figure
14). If the wiring is reversed, the saw arbor and
the conveyor track will run in the wrong direction.
The saw blade is very sharp and can cause
personal injury. Always wear thick leather
gloves when working on or around the saw
blade.
To remove the blade:
1.
If not already done, make sure the saw is
not connected to the power source!
2.
Loosen the saw arbor lock lever.
3.
Using the blade height handwheel, raise the
blade until it is approximately
conveyor track.
4.
Open the blade access door.
5.
Using the arbor wrench, hold the blade arbor
stationary.
6.
Using the T-handle wrench, remove the
arbor bolt by rotating it counterclockwise.
7.
Remove the large blade flange and carefully
slide the blade off the arbor.
8.
DO NOT re-install the arbor bolt or flange
at this time.
Model G0524 (Mfd. Since 7/16)
Before starting the saw, make sure you have
removed the saw blade, performed the pre-
ceding assembly and adjustment instruc-
tions, and have read through the rest of the
manual and are familiar with the various
functions and safety issues associated with
this machine. Failure to follow this warning
could result in serious personal injury or
even death!
To test run the saw:
1.
2.
3.
" above the
1
4
4.
5.
DO NOT turn the conveyor track ON if the
arbor rotates clockwise. Reverse any two of
the power wires at the main terminal.

Test Run

Connect the power cord to an adequate
power source.
Put on safety glasses and make sure any
bystanders are out of the way and are also
wearing safety glasses.
At the front of the control panel, rotate the red
EMERGENCY STOP button until it springs
up. The control panel is now live and any but-
tons you push will react accordingly.
Press the MAIN MOTOR START button. The
arbor should start and run smoothly.
The arbor should spin counterclockwise.
— If the arbor spins counterclockwise, then
skip ahead to the step 6.
— If the arbor spins clockwise, DO NOT
start the conveyor track. Press the red
EMERGENCY STOP button and discon-
nect the power cord from the power
source. Phase of incoming power supply
is reversed. Open the electrical panel box
and reverse the "R" and "T" power wires
at the main terminal (see Figure 22) and
start again at step 1.
-21-

Advertisement

Table of Contents
loading

Table of Contents