R and T
Terminals
Figure 22. Close-up view of power supply termi-
nals inside electrical panel.
6.
Approximately 5 seconds after the arbor is
started, press the FEED MOTOR START
button. The conveyor track should start and
run smoothly. Note—An automatic time delay
prevents the conveyor track from starting up
until 5 seconds after the main motor has
started.
7.
Press both the MAIN MOTOR STOP and
the FEED MOTOR STOP buttons to turn the
machine off.
8.
Disconnect the machine from the power
source.
9.
Install the saw blade by reversing the steps
in the "Remove the Blade" subsection on the
previous page. Note—Make sure the blade
is NOT making contact with any part of the
conveyor track.
-22-

Scale Calibration

The distance between the right edge of the blade
teeth and the fence face should be equal to the
scale reading on the fence rail. The scale can
be adjusted back and forth once the two Phillips
head screws (Figure 23) are loosened.
Figure 23. Phillips head screws securing
the fence scale.