Restarting The Appliance; Clear Space; Tuning - Quadra-Fire TREKKER INSERT series Owner's Manual

Trekker insert pellet appliance
Table of Contents

Advertisement

TREKKER INSERT
L.
Your Pellet Appliance's General Operating
Parts
Baffle Latch
Ash Dump Lever
Baffle
Figure 12.1
M. Restarting the Appliance
Restart Process:
1. When the unit has run out of fuel and the "feed error"
code is displayed, add pellet fuel to the hopper.
2. Dump the ashes and clinkers built up in the fire pot by
pulling the ash dump removal handle out several times.
Make sure clinkers have dropped into the ash pan then
return the handle to fully closed position.
3. If needed perform a manual feed; refer to section on
manual feed.
Restarting After a Power Failure:
1. For an electrical disruption the appliance will start on
its own without need for manual feed - providing the
control system is asking for heat.
2. The appliance will always go through a normal
shutdown sequence before restarting.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
Do not touch glass until it is cooled.
NEVER allow children to touch glass.
Keep children away.
CAREFULLY SUPERVISE children in same room as
appliance.
Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
12
N. Clear Space
Mantel:
Hopper
Switch
Avoid placing candles and other heat-sensitive ob jects on
mantel or hearth. Heat may damage these objects.
Firepot
O. Tuning
The function of tunning is to allow for variations in
elevation, venting and installation configurations, and fuel
types (hard wood/soft wood).
Rotating this dial will adjust the air/fuel ratio to the
appliance:
A properly adjusted fire will have a bright, active flame
pattern that extends out of the fire pot approximately 6 to 9
inches when burning on high. A properly adjusted fire will
burn cleaner and have higher efficiencies.
Figure 12.2
7082-154E
NOTICE: Clearances may only be reduced by means
ap proved by the regulatory authority having
jurisdiction.
WARNING
Fire Risk
Do NOT operate appliance:
With appliance door open.
Fire pot floor open.
Do NOT store fuel:
Closer than required clearances to
combustibles to appliance
Within space required for loading or ash
removal.
(Factory default setting is 5)
Increase the tunning number to increase the flame
height.
Decrease the tunning number to decrease flame
height.
Adjust 1 level at a time, allowing 15 minutes for fire to
stabilize before making another adjustment.
8:30 AM

TUNING

January 8, 2019