SYMPTOM
Appliance starts and stops
frequently
Slow or smoky start-up and/or
lazy flame
Convection blower fails to start
Convection Blower fails to shut
off
Exhaust blower fails to start
and/error 6 screen appears –
indicating a exhaust encoder
alarm.
Exhaust Blower fails to shut off
Feed Motor fails to shut off
Convection Blower makes
noise
Igniter does not turn off
22
POSSIBLE CAUSE
Area where the user interface is placed
affects temperature.
User interface located in tight spaces
effecting the on/off cycling of the
appliance.
Dirty fire pot, exhaust path, and/or
venting system.
Not enough combustion air
Misaligned igniter
Wet fuel or poor quality fuel
Convection Blower is jammed
Not electrically connected
Blower is defective
Exhaust probe not sensing correct
temperature
Defective probe
Control board is defective.
Wire short between blower and ground
- Control board is defective
Exhaust blower is jammed
Not electrically connected
Blower is defective
Control board is defective.
Wire short between blower and ground
- Control board is defective
Wire short between ground and: feed
motor, vacuum switch, hopper switch,
or safety snap disc
Control board is defective
Convection blower is dirty causing an
out-of-balance condition
Wire short between igniter and ground
– Control board is defective
7082-154E
CORRECTIVE ACTION
Check thermostat proximity to doors and windows
Inspect user interface location and make sure it is not
close to a surface that heats and cools quickly.
Clean entire appliance including: fire pot, ash build up
in firebox, fire pot area, behind baffle, firebox, exhaust
blower, venting, and ash pan.
Adjust the trim (see trim adjustment section)
Center the igniter in the chamber
Replace wood pellet fuel
Clean and remove jammed object from the blower
Connect the blower wires to its respective power wires
Replace blower
Secure the exhaust probe to exhaust blower housing –
keeping its wire away from hot surfaces
Replace probe
Replace control board
Repair wire and replace control board
Clean, and remove jammed object from the blower
Connect the blower wires to its respective power wires
Replace blower
Unplug the Bluetooth key, if exhaust blower runs,
Bluetooth key or user interface is defective
Repair wire and replace control board
Repair wire(s) and replace control board
Replace control board
Clean blower impellers
Repair wire and replace control board