K. Ignition Cycles
1. At the beginning of each ignition cycle, it is normal to
see some smoke in the firebox. The smoke will stop
once the fire starts.
2. The convection blower will automatically turn on after
your appliance has been burning for approximately
10 minutes. This blower transfers heat from your
appliance into the room, and will continue to run after
the thermostat has stopped calling for heat until the
appliance has cooled down.
3. Occasionally the appliance may run out of fuel and
shut itself down. When this happens, the red call
light will be on (See Figure 11.1 on page 11). To
restart it, fill the hopper and press the reset button
(See Figure 10.1, page 10). When you press the reset
button the red call light will go out. Release the button
and the light will come back on. You should see a fire
shortly. If not, follow the instructions on page 8, of
"Starting Your First Fire".
WARNING
Fire Risk
Do NOT operate appliance:
With appliance door open.
Fire pot floor open.
Cleaning slide plates open.
Do NOT store fuel:
Closer than required clearances to
combustibles to appliance
Within space required for loading or
ash removal.
CAUTION
HOT WHILE IN OPERATION. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY
CAUSE SKIN BURNS.
April 2, 2019
L. Restarting the Appliance
Restart Process
1. When the unit has run out of fuel, add pellet fuel to
the hopper.
2. Dump the ashes and clinkers built up in the fire pot by
pulling the ash dump removal handle out several times.
Make sure clinkers have dropped into the ash pan then
return the handle to fully closed position.
3. Press the reset button
4. The appliance will then being its startup sequence..
Restarting After a Power Failure
1. For an electrical disruption the appliance will start on its
own - providing the thermostat is asking for heat.
M. Clear Space
Mantel: Avoid placing candles and other heat-sensitive
objects on mantel or hearth. Heat may damage
these objects.
NOTICE: Clearances may only be reduced by means
approved by the regulatory authority
having jurisdiction.
Fire Risk.
Do NOT place combustible objects in front of the
appliance. High temperatures may ignite clothing,
furniture or draperies. Maintain a minimum
clearance of 3 feet (914mm) in front of appliance.
Fire Risk.
Keep combustible materials, gasoline and other
flammable vapors and liquids clear of appliance.
Do NOT store flammable materials in the
appliance's vicinity.
DO NOT USE GASOLINE, LANTERN FUEL,
KEROSENE, CHARCOAL LIGHTER FLUID OR
SIMILAR LIQUIDS TO START OR "FRESHEN UP"
A FIRE IN THIS Appliance.
DO NOT BURN GARBAGE OR FLAMMABLE
FLUIDS SUCH AS GASOLINE, NAPHTHA OR
ENGINE OIL.
DO NOT USE CHEMICALS OR FLUIDS TO START
THE FIRE.
Keep all such liquids well away from the appliance
while it is in use.
Combustible materials may ignite.
7050-802B
SANTA FE FREESTANDING
WARNING
WARNING
13