N. Restarting the Appliance
Restart Process
1. When the unit has run out of fuel and the "empty
hopper" error code illuminates, add pellet fuel to the
hopper.
2. Dump the ashes and clinkers built up in the firepot by
pulling the ash dump removal handle out several times.
Make sure clinkers have dropped into the ash pan then
return the handle to fully closed position.
3. Turn the dial control to OFF and and then up to high 2X
to prime.
4. After seeing pellets drop then turn to desired setting to
reset the appliance control system. The appliance will
then being its startup sequence.
Restarting After a Power Failure
1. For an electrical disruption the appliance will start on
its own without need for priming - providing the control
system is asking for heat.
2. The appliance will always go through a normal shut-
down sequence before restarting.
Remote Power Requirements
The remote receiver power is maintained through appli-
ance power.
The remote thermostat uses four AAA batteries.
O. Clear Space
NOTICE: Clearances may only be reduced by means
ap p roved by the regulatory authority having jurisdiction.
Mantel: Avoid placing candles and other heat-sensitive ob-
jects on mantel or hearth. Heat may damage these objects.
P. Trim Adjustment
The small dial located below the main dial control is used
to adjust the amount of combustion air for the fire. You may
need to adjust the combustion air to the fire for:
Elevation
Venting/Installation Configurations
Fuel Quality
If your fire is too large, lazy, or producing black soot, you
need MORE air. To increase the amount of combustion
air, rotate the dial clockwise one level at a time and allow
15 minutes for stabilization prior to making another adjust-
ment. If the fire continues to appear too rich turn the trim
dial setting counterclockwise to the negative numbers to
decrease fuel flow. Figure 12.1
If the fire is too small or occasionally goes out when there
are pellets in the hopper, the unit may have too much air.
To decrease the amount of combustion air, rotate the trim
dial towards zero one level at a time and allow 15 min utes
for stabilization prior to making another adjustment.
12
More Air & Less Fuel
Figure 12.1
Q. Remote Thermostat
Learning Remote Thermostat to Receiver
1. With receiver and remote thermostat powered, set the
receiver to "REMOTE" and remote thermostat to "ON".
2. Push receiver "LEARN" button momentarily - an audi-
ble tone should emit from the receiver.
3. Push the remote thermostat "MODE" button until "OFF"
shows on the screen - an audible sound should emit
from the receiver.
4. To check whether the receiver is "learned" push
"MODE" on the remote thermostat several times - an
audible sound should be heard from the receiver.
5. If no sound is heard repeat the process.
Remote Thermostat: Instructions
1. The remote thermostat activates an internal "on-off"
switch in the receiver (located in the appli ance).
2. If the remote thermostat setting is higher than its local
surrounding temperature it will signal the receiver to
turn ON; if the user setting is equal to- or less than the
local surrounding temperature then the remote thermo-
stat will signal the receiver to turn OFF.
Remote Thermostat: Setting Clock
1. Push "TIMER" on the screen of for more than two sec-
onds. The hour digit(s) should begin to flash.
2. Press the UP or DOWN buttons until the desired hour
is displayed (notice the AM - PM).
3. After setting the desired hour, press and release
"TIMER" again and the minute digits will begin flashing.
4. Press the UP or DOWN buttons until the desired min-
utes are displayed.
5. Press "MODE" or "TIMER" buttons again for more than
two seconds then release.
6. The minute digits will stop flashing, the clock has been
successfully set.
Remote Thermostat: Countdown Timer Function
1. Change the mode to "ON" (or "THERMON" with the set
point higher than the room temperature), push "TIMER"
on the screen.
2. 0:15 should appear on the screen.
3. Pressing the up and down arrows will allow for increase
and decrease of the timer (15-minute increments up to
1-hour; 30 –minute increments after 1-hour).
4. When the timer expires the remote should send an
"OFF" signal to the appliance.