Alcatel-Lucent 1643 AMS Applications And Planning Manual page 259

Access multiplexer am / access multiplexer small ams(formerly metropolis am/ams. release 1.0 through 7.2
Hide thumbs Also See for 1643 AMS:
Table of Contents

Advertisement

SHDSL Overview
SHDSL features
...................................................................................................................................................................................................................................
Electronic label
A user can remotely retrieve, on request, information of an electronic label of an NTU
or SRU. The LTU keeps this information in its database. The GUI can display the
information on request; it is not used by the LTU for any other purpose.
The following information can be retrieved:
• Module type
• Vendor SISA identifier
• Production year
• Production number
• Product identification
• Manufacturer ID
• Hardware version
• Hardware revision
SHDSL Performance Monitoring
The performance of SHDSL segments that are terminated on the LTU, SRU and NTU
can be monitored. The SHDSL standard (ITU-T Rec. G.991.2) prescribes a set of
parameters that needs to be monitored and stored in 15 minute and 24 hour bins for
near-end Performance Monitoring. The following table provides an overview of the PM
parameters:
Parameter
CV/BBE
ES
SES
LOSWS
UAS/US
...................................................................................................................................................................................................................................
365-312-801R7.2
Issue 3, May 2007
Name
Code Violation/background
Block Error
Errored Seconds
Severely Errored Second
Loss of SyncWord Second
Unavailable Second
Alcatel-Lucent - Proprietary
See notice on first page
Definition
Each CRC6 anomaly is counted a
CV/BBE during non-SES and
non-UAS seconds
Each second with one or more CRC6
anomaly is counted as an ES, unless
that second is UAS
Each second with 50 or more CRC6
anomalies (> 30%)or one or more
LOSW events is counted as an SES,
unless that second is UAS
Each second in which LOSW is
declared as LOSWS
Each second that is part of
unavailable time (UAT) is counted as
UAS. UAT is declared at the begin of
10 consecutive SES and cleared at the
begin of 10 consecutive non-SES.
12-13