Technical Specifications
1643 AMS:
• Dimensions (H x W x D) 70 x 448 x 204 mm (without the wall or rack mounting
system)
• Weight of 5 kg with an option card.
Environmental conditions
The environmental conditions applicable for the 1643 AM / 1643 AMS:
• Storage compliant with ETSI 300 019-1-1 Class 1-2, February 1992:
- Temperature range -5°C to +45°C
- Humidity of 5 to 95% without condensation.
• Transport compliant with ETSI 300 019-1-2 Class 2-3, February 1992:
- Temperature range -5°C to +45°C
- Humidity of 5 to 95% without condensation.
• The system operates with convection cooling.
• CE marking compliant with 73/23/EEC and 89/336/EEC
• ETSI EMC - The system meets the requirements of EN 300 386-2 V.1.1.3
(december 1997) for equipment installed in locations other than telecom centers.
• IEC 60950 -Ed3, 1994-04
• Optical safety compliant with IEC 60825-1 Ed 1.1 (1998/01) and IEC 60825-2 Ed
2 (2000/05).
The following table shows the environmental conditions for the 1643 AM / 1643 AMS.
The data refers to applications with and without X4IP option cards:
Power
X4IP installed
Type
Note: The X8PL and X5IP
option cards do not have
temperature limitations.
DC
No
Yes
AC
No
Yes
It is assumed that the X4IP option board is used in climate controlled environments.
Additionally, a fan unit is available for improving the air flow.
Installation in street cabinets supported (1643 AM only), when street cabinets provides
required environment conditions.
Important! Ensure that the 1643 AM / 1643 AMS units have reached room
temperature and are dry before taking them into operation.
For further information, please refer to the 1643 AM / 1643 AMS Installation
Guide.
...................................................................................................................................................................................................................................
365-312-801R7.2
Issue 3, May 2007
Min
Max
Min
Temp.
Temp
Hum.
-5
+45
5%
+5
+40
5%
-5
+45
5%
+5
+40
5%
Alcatel-Lucent - Proprietary
See notice on first page
System specifications
Max
Compliant to ETS 300
Hum
019-1-3 of February. 1992
& Amendment A1 June
1997
95%
Class 3.2
85%
Class 3.1
90%
Class 3.1E
85%
Class 3.1
10-15