Appendix A
A.1 Modbus, EIP, HART & N2 Profile Mappings
A.1.15

Profile 14

Data Description
Modbus
Reg
Site ID
30501
Date: Year
30101
Date: Month
30102
Date: Day
30103
Time: Hour
30104
Time: Minute
30105
Time: Second
30106
Inst.Flow Rate
30109
Path 1
Inst.Flow Rate
30111
Path 2
Inst.Flow Rate
30107
Avg Flow Rate
30119
Flow Rate Units
30517
Raw Flow Path 1
30133
Raw Flow Path 2
30135
Raw Flow Units
30537
Total
30143
Total Units
30557
Sonic Vel Path 1
30157
Sonic Vel Path 2
30159
Sonic Vel
30155
Sonic Vel Units
30577
Signal Strength
30167
Path 1
Signal Strength
30168
Path 2
Signal Strength
30165
Sig Strength
30593
Units
Aeration
30171
Aeration Units
30609
Specific Gravity
30237
S.G. Units
30689
Status: Spacing
10021
Path 1
Status: Empty
10022
Path 1
Status: Rate
10023
Path 1
Status: Fault
10024
Path 1
90
Profile 14 (FUS1010-5N04-5.04.05-DPCO)
Ethernet/IP
Bytes
Type
Tag Name OS Format
8
String
String_In
2
Integer Analog_In 0
2
Integer Analog_In 1
2
Integer Analog_In 2
2
Integer Analog_In 3
2
Integer Analog_In 4
2
Integer Analog_In 5
4
Real
Analog_In 6
4
Real
Analog_In 7
4
Real
Analog_In 8
4
Real
Analog_In 9
8
String
String_In
4
Real
Analog_In 10
4
Real
Analog_In 11
8
String
String_In
4
Real
Analog_In 12
8
String
String_In
4
Real
Analog_In 13
4
Real
Analog_In 14
4
Real
Analog_In 15
8
String
String_In
2
Integer Analog_In 16
2
Integer Analog_In 17
2
Integer Analog_In 18
8
String
String_In
2
Integer Analog_In 19
8
String
String_In
4
Real
Analog_In 20
8
String
String_In
1 Bit
Coil
Binary_In
1 Bit
Coil
Binary_In
1 Bit
Coil
Binary_In
1 Bit
Coil
Binary_In
HART
CMD VAR
0
UINT16
n/a
Float
n/a
Float
n/a
Float
n/a
Float
n/a
Float
n/a
Float
n/a
Float
129
10-0Ah T
Float
129
11-0Bh Q
Float
n/a
Float
129
0-00h P
4
UINT16
131
0-00h
Float
n/a
Float
n/a
8
UINT16
n/a
Float
129
33-21h S
12
UINT16
131
33-21h
Float
n/a
Float
n/a
Float
n/a
16
UINT16
n/a
Float
n/a
Float
n/a
Float
n/a
20
UINT16
n/a
Float
n/a
24
UINT16
n/a
Float
129
14-0Eh
28
UINT16
131
14-0Eh
0
UINT16
n/a
0
UINT16
n/a
0
UINT16
n/a
0
UINT16
n/a
F US Clamp-on Communications Protocol Manual
Hardware Installation Manual, 11/2015, A5E34981613-AC
N2
Type
Ad
BD(Byte)
1
ADI(Int)
1
ADI(Int)
2
ADI(Int)
3
ADI(Int)
4
ADI(Int)
5
ADI(Int)
6
ADF(Float)
1
ADF(Float)
2
ADF(Float)
3
ADF(Float)
4
BD(Byte)
9
ADF(Float)
5
ADF(Float)
6
BD(Byte)
17
ADF(Float)
7
BD(Byte)
25
ADF(Float)
8
ADF(Float)
9
ADF(Float)
10
BD(Byte)
33
ADF(Float)
11
ADF(Float)
12
ADF(Float)
13
BD(Byte)
41
ADF(Float)
14
BD(Byte)
49
ADF(Float)
15
BD(Byte)
57
DI(Dig In)
1
DI(Dig In)
3
DI(Dig In)
4
DI(Dig In)
5
Sz
8
1
1
1
1
1
1
1
1
1
1
8
1
1
8
1
8
1
1
1
8
1
1
1
8
1
8
1
8
1
1
1
1