Table 4- 11 Command 12 - Read Message; Table 4- 12 Command 13 - Read Tag, Descriptor, Date - Siemens SITRANS F US Protocol Manual

Clamp-on ultrasonic flowmeters
Hide thumbs Also See for SITRANS F US:
Table of Contents

Advertisement

Table 4- 11
Description
Message
Table 4- 12
Description
Tag
Descriptor
Date
Table 4- 13
Description
Transducer Serial Number
Transducer Limits and Min Span Units
Code
Upper Transducer Limit
Lower Transducer Limit
Minimum Span
Table 4- 14
Description
PV Alarm Selection Code
PV Transfer Function Code
PV Upper and Lower Range Units Codes
PV Upper Range Value
PV Lower Range Value
PV Damping Value (sec)
Write Protect Code
Reserved
PV Analog Value Flags
Table 4- 15
Description
Final Assembly Number
F US Clamp-on Communications Protocol Manual
Hardware Installation Manual, 11/2015, A5E34981613-AC
Command 12 - Read Message
Command 13 - Read Tag, Descriptor, Date
Command 14 - Read Primary Variable Transducer Information
Command 15 - Read Device Information
Command 16 - Read Final Assembly Number
4.1 Universal HART Commands
Byte
Format
Comments/Value
<write Message CMD 17>
0-23
Packed
Byte
Format
Comments/Value
0-5
Packed
<write Tag CMD 18>
<write Descriptor CMD 18>
6-17
Packed
<write Date CMD 18>
18-20
Date
Byte
Format
Comments/Value
Unique SN
0-2
U-24
PV Units Code
3
Enum
PV Upper Range Value
4-7
Float
PV Lower Range Value
8-11
Float
PV Span
12-15
Float
Byte
Format
Comments/Value
01 = Low
0
Enum
00 =- Linear
1
Enum
< write units CMD 35 or 44>
2
Enum
< write PV Upper Range CMD
3-6
Float
35>
< write PV Lower Range CMD
7-10
Float
35>
< write Damping CMD 34>
11-14
Float
251-none
15
Enum
250
16
Enum
0
17
Bits
Byte
Format
Comments/Value
<write FAN CMD 19>
0-2
U-24
HART Communications
41

Advertisement

Table of Contents
loading