Parameter List (By Parameter Number) - Mitsubishi Electric A800-E Instruction Manual

Hide thumbs Also See for A800-E:
Table of Contents

Advertisement

Parameter list (by parameter number)

2
PARAMETER
2.1
Parameter list (by parameter number)
The following parameters are dedicated to Ethernet communication. Set the parameters according to application. For other
parameters, refer to the Instruction Manual (Detailed) of the FR-A800/FR-F800 inverter.
Pr.
Pr.
group
190
M400
RUN terminal function selection
191
M401
SU terminal function selection
192
M402
IPF terminal function selection
193
M403
OL terminal function selection
194
M404
FU terminal function selection
195
M405
ABC1 terminal function selection
196
M406
ABC2 terminal function selection
313
M410
DO0 output selection
314
M411
DO1 output selection
315
M412
DO2 output selection
342
N001
Communication EEPROM write selection
349
N010
Communication reset selection
502
N013
Stop mode selection at communication error
541
N100
Frequency command sign selection
544
N103
CC-Link extended setting
NET mode operation command source
550
D012
selection
PU mode operation command source
551
D013
selection
Operation frequency during communication
779
N014
error
804
D400
Torque command source selection


810
H700
Torque limit input method selection


1124
N681
Station number in inverter-to-inverter link
Number of inverters in inverter-to-inverter
1125
N682
link system
1424
N650
Ethernet communication network number
1425
N651
Ethernet communication station number
1426
N641
Link speed and duplex mode selection
1427
N630
Ethernet function selection 1
1428
N631
Ethernet function selection 2
1429
N632
Ethernet function selection 3
Ethernet signal loss detection function
1431
N643
selection
1432
N644
Ethernet communication check time interval
1434
N600
Ethernet IP address 1
1435
N601
Ethernet IP address 2
1436
N602
Ethernet IP address 3
1437
N603
Ethernet IP address 4
1438
N610
Subnet mask 1
1439
N611
Subnet mask 2
1440
N612
Subnet mask 3
1441
N613
Subnet mask 4
1442
N660
Ethernet IP filter address 1
1443
N661
Ethernet IP filter address 2
1444
N662
Ethernet IP filter address 3
1445
N663
Ethernet IP filter address 4
6
PARAMETER
Name
242, 342
242, 342
0, 1
0, 1
0 to 4
0, 1
0, 1, 12, 14, 18, 24, 28,
100, 112, 114, 118, 128
0, 1, 5, 9999
1 to 3, 5, 9999
0 to 590 Hz, 9999
0 to 6
0 to 2
0 to 5, 9999
2 to 6
1 to 239
1 to 120
0 to 4
502, 5000 to 5002, 5006 to
5008, 5010 to 5013, 9999,
45237, 61450
502, 5000 to 5002, 5006 to
5008, 5010 to 5013, 9999,
45237, 61450
502, 5000 to 5002, 5006 to
5008, 5010 to 5013, 9999,
45237, 61450
0 to 3
0 to 999.8 s, 9999
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
Minimum
Setting range
setting
increments
1
1
1

1
1
1
1
1
1

1
1
1
1
1
1
1
1
0.01 Hz
1
1
1
1
1
1
1
1
1
1
1
0.1 s
1
1
1
1
1
1
1
1
1
1
1
1
Refer
Initial
Customer
to
value
setting
page
0
13
1
13
2
13

9999
13

3
13
4
13
99
13
9999
13
9999
13
9999
13
9999
13
0
14
0
14
0
14
0
51
0
51
9999
9
9999
9
9999
14
0
51
0
51
9999
72
2
72
1
19
1
19
0
19
5001
19
45237
19
9999
19
0
19
9999
19
192
19
168
19
50
19
1
19
255
19
255
19
255
19
0
19
0
19
0
19
0
19
0
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

F800-e

Table of Contents