(N) Operation via communication and its settings
CC-Link extended setting (Pr.544)
• Use this parameter to select the function of the remote registers for the CC-Link IE Field Network Basic.
Pr.544 setting
0 (initial setting)
Compatible with CC-Link Ver.1
1
Compatible with CC-Link Ver.1
12
Compatible with the double setting of CC-Link Ver.2
14
Compatible with the quadruple setting of CC-Link Ver.2
18
Compatible with the octuple setting of CC-Link Ver.2
24
Compatible with the quadruple setting of CC-Link Ver.2
28
Compatible with the octuple setting of CC-Link Ver.2
100
Compatible with CC-Link Ver.1
112
Compatible with the double setting of CC-Link Ver.2
114
Compatible with the quadruple setting of CC-Link Ver.2
118
Compatible with the octuple setting of CC-Link Ver.2
128
Compatible with the octuple setting of CC-Link Ver.2

Refer to the PLC function programming manual.
Frequency command with sign (Pr.541)
• The start command (forward/reverse rotation) can be inverted by adding a plus or minus sign to the value of the frequency
command sent through the CC-Link IE Field Network Basic.
• The Pr.541 Frequency command sign selection setting is applied to the frequency command from RWw1. (Refer to
page
58.)
Speed setting using
Pr.37 and Pr.144
Not used
With

Pr.811 is only available for the FR-A800-E.
• Relationship between the start command and sign (Pr.541="1")
Start command
Forward rotation
Reverse rotation
NOTE
• When Pr.541 = 1 (with sign)
- When EEPROM write is specified with the RYE, write mode error (error code H01) will occur.
- When concurrent execution of both RYD and RYE is enabled (when a value other than 0 is set in Pr.544) and both RYD and
RYE are turned on, RYD has precedence.
- When power is turned on (inverter reset), the initial setting status of the sign bit is "positive" and the set frequency is "0 Hz".
(The motor does not operate at the frequency set before turning OFF the power (inverter reset).)
- When set frequency is written with the instruction code of HED and HEE, the sign of the frequency command is not
changed.
• Setting Pr.811 Set resolution switchover ="1 or 11" changes the increment from 1 r/min to 0.1 r/min.
52
PARAMETER
Description
Pr.541
Sign
setting
0
Not used
0 to 59000
1
With
-32768 to 32767 (two's complement)
0
Not used
0 to 65535
1
With
-32768 to 32767 (two's complement)
Sign of the frequency command
+
-
+
-
PLC function
Setting range
0 to 590.00 Hz
-327.68 to 327.67 Hz
Actual run command
Forward rotation
Reverse rotation
Reverse rotation
Forward rotation
Refer to page
53
54
54
54
55
54
55

Actual frequency command
It depends on Pr.37, Pr.144, Pr.811
(in 1 or 0.1 increments)
