Faults History; Model Information Monitor - Mitsubishi Electric A800-E Instruction Manual

Hide thumbs Also See for A800-E:
Table of Contents

Advertisement

(N) Operation via communication and its settings
Pr.
Register
42118
Terminal 6 bias (torque)
C35 (928)
Terminal 6 bias (torque)
43928
(terminal analog value)
C36 (929)
41929
Terminal 6 gain command (torque)
42119
Terminal 6 gain (torque)
C37 (929)
Terminal 6 gain (torque)
43929
(terminal analog value)
C8 (930)
41930
Current output bias signal
C9 (930)
42120
Current output bias current
C10 (931)
41931
Current output gain signal
C11 (931)
42121
Current output gain current
Terminal 4 bias command (torque/
C38 (932)
41932
magnetic flux)
42122
Terminal 4 bias (torque/magnetic flux)
C39 (932)
Terminal 4 bias (torque/magnetic flux)
43932
(terminal analog value)
Terminal 4 gain command (torque/
C40 (933)
41933
magnetic flux)
42123
Terminal 4 gain (torque/magnetic flux)
C41 (933)
Terminal 4 gain (torque/magnetic flux)
43933
(terminal analog value)
C42 (934)
41934
PID display bias coefficient
42124
PID display bias analog value
C43 (934)
PID display bias analog value
43934
(terminal analog value)
C44 (935)
41935
PID display gain coefficient
42125
PID display gain analog value
C45 (935)
PID display gain analog value
43935
(terminal analog value)
Refer to the Instruction Manual
1000 to
45000 to
(Detailed) of the FR-A800/FR-F800
1999
45359
inverter for parameter names.

• Faults history

Register
40501
Faults history 1
40502
Faults history 2
40503
Faults history 3
40504
Faults history 4
40505
Faults history 5
40506
Faults history 6
40507
Faults history 7
40508
Faults history 8

• Model information monitor

Register
44001
Inverter type (1st and 2nd characters)
44002
Inverter type (3rd and 4th characters)
44003
Inverter type (5th and 6th characters)
44004
Inverter type (7th and 8th characters)
44005
Inverter type (9th and 10th characters)
44006
Inverter type (11th and 12th characters)
44007
Inverter type (13th and 14th characters)
44008
Inverter type (15th and 16th characters)
44009
Inverter type (17th and 18th characters)
44010
Inverter type (19th and 20th characters)
44011
Capacity (1st and 2nd characters)
44012
Capacity (3rd and 4th characters)
44013
Capacity (5th and 6th characters)
NOTE
• When a 32-bit parameter setting or monitor item is read and the value to be read exceeds HFFFF, HFFFF is returned.
50
PARAMETER
Parameter name
Definition
Read/write
Read/write
Read
Read
Read
Read
Read
Read
Read
Definition
Read/write
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read/write
Read/write
Analog value (%) set to C35 (928)
Analog value (%) of the voltage applied to terminal 6 of
Read
the FR-A8AZ
Read/write
Read/write
Analog value (%) set to C37 (929)
Analog value (%) of the voltage applied to terminal 6 of
Read
the FR-A8AZ
Read/write
Read/write
Analog value (%) set to C9 (930)
Read/write
Read/write
Analog value (%) set to C11 (931)
Read/write
Read/write
Analog value (%) set to C39 (932)
Analog value (%) of the current (voltage) applied to
Read
terminal 4
Read/write
Read/write
Analog value (%) set to C41 (933)
Analog value (%) of the current (voltage) applied to
Read
terminal 4
Read/write
Read/write
Analog value (%) set to C43 (934)
Analog value (%) of the current (voltage) applied to
Read
terminal 4
Read/write
Read/write
Analog value (%) set to C45 (935)
Analog value (%) of the current (voltage) applied to
Read
terminal 4
Read/write
The parameter number + 44000 is the register number.
Being 2 bytes in length, the data is stored as H00.
Refer to the lowest 1 byte for the error code. (Refer to the list of
fault displays in the Instruction Manual (Detailed) of the FR-A800
inverter for error codes.)
Performing write using the register 40501 batch-clears the faults
history.
Set any value as data.
The inverter type can be read in ASCII code.
H20 (blank code) is set for blank area.
Example) For the "FR-A840-E1 (FM type)",
H46, H52, H2D, H41, H38, H34, H30, H2D, H45, H31, H20...H20
The capacity in the inverter model can be read in ASCII code.
Data is read in increments of 0.1 kW, and rounds down to 0.01 kW
increments.
H20 (blank code) is set for blank area.
Example) 0.75K..."
7"
(H20, H20, H20, H20, H20, H37)
Remarks
Remarks
Remarks

Advertisement

Table of Contents
loading

This manual is also suitable for:

F800-e

Table of Contents