Mounting an Automatic Gun

Mounting an Automatic Gun

Mounting to a rod

1.
To mount the gun on a 1/2 in. diameter rod, insert
the bar (A) through the hole in the gun body as
shown.
2.
Secure the gun to the bar by tightening 1/4 in. - 20
mounting screws.

Connecting Airline and Accessories

1.
On the gun air supply line, install an air pressure
regulator.
A minimum of 80 psi (0.55 MPA, 5.5 bar) air
pressure must be supplied to the gun for proper
operation.
A four-way air valve, which exhausts cylinder air
in both directions, is required.
2.
On the gun air supply line, install a bleed-type air
shutoff valve downstream of the gun air regulator.
12
Mounting to a stationary
support robotic arm
To mount gun to stationary support or robot arm, see
mounting hole dimensions, page 53.
Two .128 in.
alignment
pin holes
ti5007b
Four M5 x 0.08 in. (6.3 mm) holes
3.
On the main air line, install a bleed-type air shutoff
valve.
Clean off air
Three 1/8 npt
ports (air
inlet)
P
I
O
I - Activation
P - Purge/Clean-off
O - Deactivation
I
P
O
Gun
deactuation
ti4751b
I - Activation
P - Purge/Clean-off
O - Deactivation
Two 1/4 -
20 unc
holes
ti4751b
Gun
actuation