Operation

Spraying

1.
To spray, turn RAC tip (X) to spray position.
X
2.
Close solvent purge knob (V).
V
3.
Trigger gun to spray.
WARNING
Read warnings page, 4.
Flushing with Solvent Purge
Assembly
1.
Detrigger the gun and engage safety lock.
310648P
2.
TI5096b
3.
4.
TI5004b
5.
Turn RAC tip (X) to clean position.
X
Hold gun into a grounded metal pail, holding a
metal part of fluid manifold firmly to side of pail.
Open the solvent purge knob (V) to introduce sol-
vent to the static mixer assembly.
V
When static mixer and tip are clean, close solvent
purge knob (V).
V
For more thorough static mixer cleaning,
remove the spray tip.
Minimize the amount of flushing time. Do not
atomize solvent.
Operation
TI5097b
TI5110b
TI5004b
17