Foam Resins With 245 Fa Blowing Agents; Changing Materials; Grounding - Graco Fusion Instructions-Parts List Manual

Solvent purge plural component gun for use with non-flammable foam and polyurea. for professional use only. not for use in explosive atmospheres.
Table of Contents

Advertisement

Foam Resins with 245 fa
Blowing Agents
Some foam blowing agents will froth at temperatures
above 90°F (33°C) when not under pressure, especially
if agitated. To reduce frothing, minimize preheating in a
circulation system.

Changing Materials

NOTICE
Changing the material types used in your equipment
requires special attention to avoid equipment damage
and downtime.
When changing materials, flush the equipment
multiple times to ensure it is thoroughly clean.
Always clean the fluid inlet strainers after flushing.
Check with your material manufacturer for chemi-
cal compatibility.
When changing between epoxies and urethanes
or polyureas, disassemble and clean all fluid com-
ponents and change hoses. Epoxies often have
amines on the B (hardener) side. Polyureas often
have amines on the B (resin) side.
310648P

Grounding

WARNING
Read warnings, page 4.
Check your local electrical code and proportioner man-
ual for detailed grounding instructions.
Solvent line must be Graco approved grounded hose.
Primary ground is through the grounded solvent supply
hose.
Ensure that solvent supply pump is properly grounded.
Ensure continuity from the spray tip to grounded solvent
hose when using static mixers and tips other than sup-
plied with gun.
Grounding
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

248597 248647248603

Table of Contents