Slip-Fit Polycarballoy Mix Module - Graco Fusion Instructions-Parts List Manual

Solvent purge plural component gun for use with non-flammable foam and polyurea. for professional use only. not for use in explosive atmospheres.
Table of Contents

Advertisement

Repair
Slip-Fit Polycarballoy Mix
Module
See page 50 for available Slip-Fit Polycarballoy Mix
Module sizes.
1.
Follow Pressure Relief Procedure, page 19.
2.
Flush Gun, page 24.
3.
Remove fluid manifold (G). Leave air connected.
G
4.
Remove RAC tip and guard (9, 63), static mixer
(40), and solvent purge assembly (28).
28
40
9, 63
5.
Remove mix module nut (25), using a wrench.
Remove front seal (46).
25
46
34
6.
Disengage piston safety lock (L), page 10. Trigger
and detrigger gun once to release mix module (39)
from fluid housing (7). Remove mix module.
Engage piston safety lock.
39
If mix module (39) does not protrude from fluid
housing (7), slightly loosen then retighten lock
ring (11), to allow gripping of edge for removal.
7.
Push mix module (39) onto rod (31) as far as pos-
sible.
39
TI4972b
TI5032b
TI3843a
11
7
31
7
L
TI3845a
TI3845a
310648P