7 Maintenance

After servicing, complete the relevant
Service
Record
Benchmark Checklist located on the
inside back pages of this document. To
meet with warranty requirements the
cylinder must be serviced annually.
The maintenance of this
appliance must be carried
out by a suitably qualified
person
recommended to maintain
the unit on an annual basis.
Isolate
supplies
before commencing work.
Danger of electrical shock!
1)
Draw some water from cold water
tap and retain in container.
2)
Isolate cold water mains supply
from cylinder.
3)
Briefly
open
pressure relief valve, assure safe
discharge and check that valve is
not dripping when closed.
4)
Briefly
open
valve, assure safe discharge and
check that valve is not dripping
when closed. The expansion relief
valve should be operated regularly
to remove lime deposits and to
verify that it is not blocked.
5)
Open hot water tap and release
remaining pressure from unit.
6)
If
the
system
completely
inspection, ensure the hot water
tap remains open, connect a hose
to the drain valve and ensure a
safe discharge.
section
of
the
only.
It
is
all
electrical
from
the
unit
temperature
and
expansion
relief
is
drained
for
an
internal
Maintenance
7)
Note the set pressure of the
pressure reducing valve. Remove
cartridge and clean strainer in
water provided in container. Re-
assemble pressure reducing valve
ensuring the correct pressure is
set.
8)
Periodically the immersion heaters
should be removed cleaned and
the unit flushed out. Check the O-
ring seal for damage and replace if
necessary.
9)
Check
electrical
connections and the condition of
the cable of the immersion heater
and the thermostat.
10) The immersion heater boss can
also be used for access to view the
internal
components
cylinder.
11) Re-commission unit (see chapter
6).
If the cylinder is not in use for
excess of 1 month, it must be
drained down by a competent
person and recommissioned before
use. Note: The immersion must be
switched off at the mains before
draining the cylinder.
If replacement parts are required,
please see Figure 11 for part
descriptions and part numbers.
wiring
of
the

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecsd250-580Ecsd150-580Ecsd210-580Ecsd300-580

Table of Contents