Reference
Weight [kg]
Reheat time [mins]*
Heat Loss [kWh]
Height [mm]
Outer Diameter [mm]
HW Outlet [mm]
T&P valve [mm]
CW Inlet [mm]
Bottom Immersion [mm]
Top Immersion [mm]
Note: All measurements are taken from the base of the cylinder to the mid-point on the item.
* Determined in accordance with EN160335-2-21.
GDC Group Ltd
Reference
Load Profile – Primary
Energy Rating
Energy Efficiency
Annual Energy
Consumption
Load Profile –
Secondary
Set Temperature
Sound Level [dB]
Operating Mode
V-40
Direct Electric Cylinder Range - Dimensions
Table 5: Direct Electric Cylinder Product Dimensions
Direct Electric Cylinder Range – Product Fiche
ECSd125-
580
M
C
36%
1411
-
60°C
15dB
Off Peak
204
Table 6: Direct Electric Cylinder Product Fiche
Technical Data
125
150
210
23
26
33
122
150
218
0.95
1.10
1.41
945
1115
1490
580
580
580
720
890
1265
720
890
1265
180
180
180
200
200
200
695
560
1070
ECSd150-
ECSd210-
580
580
M
M
C
C
37%
36%
1389
1435
-
-
60°C
60°C
15dB
15dB
Off Peak
Off Peak
242
355
250
300
39
46
284
313
1.51
1.96
1765
2065
580
580
1540
1840
1540
1840
180
180
200
200
1345
1645
ECSd250-
ECSd300-
580
580
L
L
C
C
37%
37%
2739
2774
M
M
60°C
60°C
15dB
15dB
Off Peak
Off Peak
415
490

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecsd250-580Ecsd150-580Ecsd210-580Ecsd300-580