1380
W302
Number of the horizontal PLC soft
key that was pressed
W304
Number of the vertical PLC soft key
that was pressed
Module 9203 Activate PLC soft-key menu
The PLC soft-key project can be defined in such a way that it is effective only
for specific modes of operation. This might be useful, for example, if you want
to use different PLC soft-key projects for the machine and programming
modes of operation.
The module supplies the resource handle for Modules 9204 to 9208.
Call:
PS
D
<Resource handle>
0 when it is called for the first time, otherwise
Resource handle from Module 9203
PS
B/W/D/K/S<0>
0 or "" is given (is no longer evaluated)
PS
B/W/D/K <Number of PLC soft-key menu>
Number of the soft-key menu
Value < 0:
- Returns the current resource handle
PS
B/W/D/K <Mode>
1: Vertical PLC soft-key row
PS
B/W/D/K <Mode of operation>
0: Programming modes of operation
1: Machine modes of operation
2: Programming and machine modes of operation
CM
9203
PL
D
<Resource handle>
0: Error code in W1022
Error code:
Marker
Value
Meaning
M4203
0
No error
1
Error code in W1022
W1022
2
Resource-handle overflow, incorrect resource handle,
incorrect mode, incorrect operating mode or number of
PLC soft-key root menu negative.
3
Incorrect string number or incorrect string
20
Module was not called in a spawn or submit job
44
Error in the resource file
HEIDENHAIN Technical Manual iTNC 530 HSCI
Set
Reset
NC
NC
NC
NC