Module 9203 Activate Plc Soft-Key Menu - HEIDENHAIN iTNC 530 HSCI Technical Manual

Hide thumbs Also See for iTNC 530 HSCI:
Table of Contents

Advertisement

1380
W302
Number of the horizontal PLC soft
key that was pressed
W304
Number of the vertical PLC soft key
that was pressed

Module 9203 Activate PLC soft-key menu

The PLC soft-key project can be defined in such a way that it is effective only
for specific modes of operation. This might be useful, for example, if you want
to use different PLC soft-key projects for the machine and programming
modes of operation.
The module supplies the resource handle for Modules 9204 to 9208.
Call:
PS
D
<Resource handle>
0 when it is called for the first time, otherwise
Resource handle from Module 9203
PS
B/W/D/K/S<0>
0 or "" is given (is no longer evaluated)
PS
B/W/D/K <Number of PLC soft-key menu>
Number of the soft-key menu
Value < 0:
- Returns the current resource handle
PS
B/W/D/K <Mode>
1: Vertical PLC soft-key row
PS
B/W/D/K <Mode of operation>
0: Programming modes of operation
1: Machine modes of operation
2: Programming and machine modes of operation
CM
9203
PL
D
<Resource handle>
0: Error code in W1022
Error code:
Marker
Value
Meaning
M4203
0
No error
1
Error code in W1022
W1022
2
Resource-handle overflow, incorrect resource handle,
incorrect mode, incorrect operating mode or number of
PLC soft-key root menu negative.
3
Incorrect string number or incorrect string
20
Module was not called in a spawn or submit job
44
Error in the resource file
HEIDENHAIN Technical Manual iTNC 530 HSCI