Test Operation (Navigation area)

4.4

Test Operation (Navigation area)

Frequency (fault) indication, operation mode indication and switching, sending of forward/reverse rotation command and
writing of the set frequency is available.
Note
For safety issue, command sending part of Test Operation is hidden at start up of FR Configurator.
When performing Test Operation, check [Test Operation] sub-menu under [Navigation] of [View] menu to display the
command sending part of Test Operation.
Do not click repeatedly each operation buttons,
the FR Configurator. If operation continues unintentionally, press
4.4.1

Test Operation screen

No.
Name
Frequency (Speed)
A
indication
Set frequency (speed) input
B
field
C
SET
D
STOP
E
PU
F
EXT
G
NET
H
Operation mode indication
I
Rotation direction indication
J
FWD
K
REV
90
E
A
B
Shows frequency (speed) or fault indication etc. of the selected inverter.
Input the set frequency and click
while the field is empty shows the output frequency of the selected station.
Writes the value of "Frequency (speed) input" field as the set frequency of the selected inverter.
Sends stop command to the selected inverter.
Changes the operation mode of the selected inverter to PU operation mode.
Changes the operation mode of the selected inverter to external operation mode.
Changes the operation mode of the selected inverter to network operation mode.
Shows the operation mode of the selected inverter in red.
At forward rotation, "FWD" turns red, and at reverse rotation "REV" turns red.
Sends forward rotation command to the selected inverter. Performing test operation during the button
is pressed. (When Release Test Operation is selected, clicking button once keeps operation. Refer to
page 85)
Sends reverse rotation command to the selected inverter. Performing test operation during the button
is pressed. (When Release Test Operation is selected, clicking button once keeps operation. Refer to
page 85)
Only this part is displayed.
Command sending part of Test Operation is hidden.
and
. Doing so may result in unstable operation of
to stop operation.
F
G
C
D
Function and description
to write the set frequency to the selected inverter. Pressing
H
I
J
K

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e700 seriesFr-f700 seriesFr-d700 series

Table of Contents