Monitoring

The RTR-57C can be set to patrol and monitor RTR-51/52/53 or
RVR-52 groups and display in order the current readings for view.
1.
In the Main Menu, open [ MONITOR MODE].
2.
Select the monitoring range.
[All Groups] :
Remote Units in all groups registered to the RTR-57C will be contacted
via wireless communication, and current measurement readings for those
units with which communication is possible will be displayed consecutively
every 2 seconds. This can be done for up to 120 units; the 121
reading cannot be displayed.
[Specify Group] :
All Remote Units in the selected groups will be contacted via wireless
communication, and current measurement readings for those units will be
displayed consecutively every 2 seconds.
For those units with which communication is impossible the measurement
will be displayed as [----].
3.
Select and set the Monitoring Interval
[Interval] :
The monitoring interval is the amount of time between the starting of
wireless communication to gather current Remote Unit readings. Selections
can be made from 15 sec, 30 sec, and 1 to 60 minutes (in 1 minute units).
NOTE:
The amount of communication time depends on the number of registered
groups and remote units. Please note that if the monitoring interval is set
for less time than communication takes to complete a round of monitoring,
the system will automatically extend the interval to allow for the necessary
amount of communication time.
47
NOTE:
The shorter the monitoring interval the sooner batteries will loose their
power.
<Communication Time for [All Groups] >
・If there are 64 Remote Units registered to the group
(24 seconds per group x Number of groups)
・If there are 250 Remote Units registered to the group
(54 seconds per group x Number of groups)
Moreover, the display time for each unit is about 2 seconds.
<Communication Time for [Specify Groups]>
unit's
st
The communication time will depend on the number of registered remote
units. For 250 units registered to 1 group the time will be 54 seconds plus a
display time for each unit of 2 seconds.
4.
By selecting the monitoring range and clicking, the monitoring
search will begin.
If using [Specify Group], by specifying the group and clicking, the
monitoring search will begin.
5.
After the search has been completed, the current measurement
readings for those remotes registered in the group(s) will be
consecutively displayed.
For RTR-53, the display will show in the order of temp / humidity.
If the buzzer has been set to ON and a result is NG, a beeping sound will
go off.
【If the upper and lower limit
settings are activated.】
Result
Upper and Lower Limits