Connect Power To A Dc Router - Juniper ACX5448 Quick Start Manual

Universal metro router
Hide thumbs Also See for ACX5448:
Table of Contents

Advertisement

Route the power cord appropriately. Verify that the power cord does not block the air exhaust and access to router components,
9.
or drape where people could trip on it.
Power on the power supply at source.
10.
Repeat Step
3
through Step
11.
Figure 17: Connecting an AC Power Cord to an ACX5448

Connect Power to a DC Router

Table 3
gives the DC power system input voltage for the ACX5448 router.
Table 3: ACX5448 DC Power System Input Voltage
Item
DC input voltage
To connect power to a DC router:
Attach the grounding strap to your bare wrist and to a site ESD point.
1.
Verify that the DC power cables are correctly labeled before making connections to the power supply. In a typical power
2.
distribution scheme where the return is connected to chassis ground at the battery plant, you can use a multimeter to verify
the resistance of the –48V and RTN DC cables to chassis ground:
The cable with very low resistance (indicating a closed circuit) to chassis ground is positive (+) and will be installed on the
V+ (return) DC power input terminal.
The cable with very high resistance (indicating an open circuit) to chassis ground is negative (–) and will be installed on the
V– (input) DC power input terminal.
CAUTION:
You must ensure that power connections maintain the proper polarity. The power source cables might
be labeled (+) and (–) to indicate their polarity. There is no standard color coding for DC power cables. The color
coding used by the external DC power source at your site determines the color coding for the leads on the power
cables that attach to the DC power input terminals on each power supply.
Ensure that the input 2-pole circuit breaker is open so that the voltage across the DC power source cable leads is 0 V and that
3.
the cable leads do not become active while you are connecting DC power.
NOTE:
The V+ terminals are referred to as +RTN, and V– terminals are referred to as –48 V in DC Power Wiring
Sequence Warning.
Copyright © 2018, Juniper Networks, Inc.
9
for the installing the remaining power supply.
Specification
Rated operating voltage: –48 VDC to –60 VDC
Operating voltage range: –40.8 VDC through –72 VDC
ACX5448 Universal Metro Router Quick Start Guide
11

Advertisement

Table of Contents
loading

Table of Contents